>BORATOR1ES, INC AIR SAMPLE ANALYSIS REPORT PHASE CONTRAST MICROSCOPY

CLIENT: WARREN & PANZER ENGINEERS, P,C. TURNAROUND TIME a^HRS WKPFILE# S01-O1 SAMPLE DATE «/,7ra2 WKPLOGI.O.# N 0206129, N02O6130, and NC20ei31 RECBIVED DATE 8n7O2 Contract#: VVrCAR2 ANALYSIS DATE

REPORT DATE wia«2 CUENTJOB: NYC Department cf Environmental Protection CLIENT JOB#; 1079.01.01 LOCATION S.W. Area/Site Map ANALYSIS; AIRBORNE FIBER COUNTING. PHASE CONTRAST MICROSCOPY. NIOSH 7400. NIOSH PAT Lab NO, 07186; NY COLLECTION DEVICE; 25 mm MCE Filter Cassette: Collection Area » 365 sq mm;

Sample were collected by; Warren and Panzer

SUMMARY OF ANALYSIS

CLIENT FIBERS/ FIBERS/ SAMPLE# SHe# SAMPLE LOCATION Vol. eq mm cc

1079.01.01 001 27 Gateway Plaza Park Area 675 2.50 <0.004 002 31 South End Ave. and Albany Street 675 5.10 <0.004 003 32 Wart straei ar»d Abany Place 675 3.80 <0.004 004 33A Rector Place by the Park Place 675 2.50 <0.004 005 34 W. Thames Street - Along Waterfront 675 6.40 <0.004 006 37 West of Third Place 675 7.60 0.004 007 8 West Street and Warren Street 675 7.60 0.004 006 4 River Terrace and Chambers Street 675 2.50 <0.004 009 ex River Terrace Park Area Between Park Place and Warren Street 675 7.60 0.004 010 8 River Terrace and Park Place West 675 S.10 <0.004 011 17 River Terrace and Vesey 675 5.70 <0.004 012 7 Warren Street and North End Avenue 675 5.10 <0004 013 10 North End Avenue Park piece Yiieet 675 11.50 0.007 014 29 Trinity Place and Thames Street 875 6.40 <0.004 015 21 Fulton and Church Street 675 14.00 0.006 016 20A Vesey Street and West Broadway 675 3.20 <0.004 017 16 Park place and Church Street 675 8.90 0.005 018 12 Murray Street and Church Street 675 1040 0.006 019 15 Park Place and Greenwich Street 675 1040 0.006 020 11 Murray Street and Greenwich Street 675 8.90 0.005 021 Field Blank 0.00 022 Field Blank 0,00

NOTES: 15.3 fibers/100 fields was used to calculate the liniit of detection (LOO). 2. Samples were not collected by WKP Laboratories, inc 3. The Federal EPA Clearance Critical following an asbestos abatement project is 0.010 fibers/cc. 4. PCM air samples will be disposed of after 3 months unless otherwise directed by cffent in writing.

O.M.

laboratory analyst laboratory DIRECTOR

CITY_21MC100_003005302

NYC-WTC_000348142

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348142Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348079

Airborne fiber counting per NIOSH 7400; NYC DEP project.

Similar indexed content

Compare copies and versions →