Air sample analysis report, phase contrast microscopy, 2002

Machine-extracted title · confidence 32%

Air sample analysis report (phase contrast microscopy) for NYC DEP project, Warren & Panzer Engineers.

NYC-WTC_000348140
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

WKP LABORATORIES, INC AIR SAMPLE ANALYSIS REPORT PHASE CONTRAST MICROSCOPY

CLIENT: WARREN & PANZER ENGINEERS, P,C. J4HRS TWRfiAflOUNOTIMe WKP FILE # sol-01 €71MK SAMPLSOATe WKP LOG 1.0. # N0206137. N0206136, sna N0206I39 fttCCIVED QA.TE 671 MS Contrad#' WTC AR2 AMAIVSW OAie

REPORT DATE «/1WQ2 CLIENT JOB; NYC Department of Environmental Prorecficn CLIENT JOB#: 1079.01.01 LOCATION S.W. Ama/Site Map ANALYSIS. AIRBORNE FIBER COUNTING, PHASE CONTRAST MICROSCOPY. NIOSH 7400. MOSH PAT Lab NO. 07186: NV COLLECTION DEVICE: 25 mm MCE Filter CBSsetts. Collection Area = 3B5 .to mm;

SAMPLE WERE COLLECTEO BY; Warren and Panier

SUMMARY OF ANALYSIS client FIBERS/ FIBERS/ SAMPLE# Site# SAMPLE LOCATION Vet. sd mm co 1079.01.01 001 2? Gateway Plaza Park Area 675 10.80 0.006 002 31 South End Ave. ertd Albany Street 675 4.50 ■40.004 003 32 West Sireat and Albany Place 675 380 <0.004 004 33A Rector Place by the Park Place 675 8.90 0.005 005 34 W. Thames Stieat - Along Waterfront 675 6.40 <0 004 006 37 West of Third Place 675 10.20 0.C06 007 e West Street and Warren Street 675 0.00 <0.004 006 River T errace and Chambers Street 873 7.60 0004 009 6A River Terrace Path Area SeNveen Park Place and Warren Street 675 14.00 0.008 010 9 River Terrace and Park Place West 675 7.B0 0.0O4 on 17 River Terrace and Vasey 875 6.40 <0 004 012 7 Warren Street and North End Avenue 675 2.S0 <0.004 013 10 North End Avenue Park place West 67S 2.50 <0.004 014 29 Trinity Place and Thames Sheet 675 3.80 <0.004 015 21 Fullon and Church Street 675 7.00 0.004 016 2CA Vesey Street and West Broadway 675 6.40 <0.004 017 18 Park place and Church Street 67S 760 0.004 018 12 Murray Street and Church Street 675 11.50 0.007 019 15 Park Place and Greenwich Street 675 1270 0.007 020 11 Murray Street and Greenwich Strast 675 7 80 0.004 021 Field Stank 0.00 022 Reid Slenk 000

NOTES; 1,5-5 fibers/lOO fields was used to calojlale the limit of detection (LOD). 2. Samples were not collected by WKP Laixiratories, Inc. 3. The Federal EPA Clearance Critical fallowing an asbestos abatement project is 0 01C fibere/cc. 4. PCM air samples will be disposed of after 3 months unless otharw.se directed by dienl In writing.

D.M.

W0ORATORY analyst WaORATORY DIRECTOR

CITY_21MC1OO_OO3OO5298

NYC-WTC_000348140

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348140Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348112

Airborne fiber counting with phase contrast microscopy for NYC DEP, 6/27/02.

Similar indexed content

Compare copies and versions →