-WKP LABORATORIES, INC AIR SAMPLE ANALYSIS REPORT PHASE CONTRAST MICROSCOPY CLIENT: WARREN & PANZER ENGINEERS, P.C, TURN AROUND TtME JAHRS WKP FILE* 501-01 SAMPLE OATE SlilTm WKPLOGI.D.# N0206222. N020S223 and NO206224 R6C&V6O DATE Contract P: WTCAR2 ANALYSIS DATE 807*02
REPORT DATE 028*02 CLIENT JOB; NYC Department of Environmental Protection CUENTJOB*; 1079.01.01 LOCATION S .W. Area/Site Map ANALYSIS: AIRBORNE FIBER COUNTING, PHASE CONTRAST MICROSCOPY. NIOSH 7400. NIOSH PAT Lab NO. 07186; MY COLLECTION DEVICE: 25 mm MCE Filter Cassene; Collection Area = 355 sq mm;
SAMPLE WERE COLLECTED BY: Warren and Panier Engineers, P.C.
SUMMARY OP ANALYSIS CLIENT FIBERS/ FIBERS/ SAMPLE* Site* SAMPLE LOCATION Vol. sq mm cc
1079.01.01 001 27 Gateway Plaza Park Area 675 1,30 <0.004 002 31 South End Ave. and Albany Streel €75 0.00 <0.004 003 32 West Slreel and Albany Place 675 2.50 <0.004 004 33A Rector Platte by the Park Place 675 0.00 <0.004 005 34 W. Thames Street - Along Waterfront 676 3.80 <0.004 006 37 West of Third Place 675 7.00 0.004 007 5 West Street and Warren Street 675 2.S0 <0.004 008 4 River Terrace and Chambers Slreel 676 6.40 <0.004 009 6A River Temace Park Area Between Park Place and Warren Street 675 760 0.004 010 9 River Terrace and Park Place West 675 5.10 <0,004 011 17 River Terrace and Vesey 675 5.10 <0.004 012 7 warren Slreel and North End Avenue 675 1.30 <0.004 013 10 North End Avenue Park place West 675 1.30 <0.004 014 29 Trinity Place and Thames Street 675 4.50 <0.004 01s 21 Fulton and Church Street 675 10.20 0 006 016 20A Vasey Street and West Broadway 675 0.00 <0.004 017 16 Park place and Church Street 676 3.60 <0,004 016 12 Murray Street and Church Street 675 G.SO O.OOS 019 15 Park Place and Greenwich Street 675 2.50 <0.004 020 11 Murray Street and Greenwich Street 675 7.60 0.004 021 Field Blank 0.00 022 Field Blank 0.00
NOTES. 1.5.5 tibersIlOO fieWs was used to calculate the limit of detection (LOO). 2. Samples were not collected by WKP Latxjratories. Ine. 3. The Federal EPA Clearance Critical following an asbestos abatement project Is 0.010 fibers/cc 4. PCM air samples will be disposed of after 3 months unless otherwise directed by client in writing.
D.M. laboratory analyst i-ABORATORY CIRECTOR
CITY_21MC1OO_OO3OO5255
NYC-WTC_000348112
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000348049
Airborne fiber counting and phase-contrast microscopy; NYC DEP job 1079.01.01, July 2002.
14 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348052
Phase-contrast microscopy and airborne fiber counting for NYC DEP, July 2002.
15 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000206737
Laboratory report detailing phase contrast microscopy results for airborne fiber counting at the S.W. Area site collected on June 30, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348164
Airborne fiber counting by phase contrast microscopy for NYC DEP job; 8/18/2? report date appears.
11 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000206730
Laboratory report detailing phase contrast microscopy results for airborne fiber counting at the S.W. Area site collected on July 18, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348130
Air sample analysis report (phase contrast microscopy) for NYC DEP project, Warren & Panzer Engineers.
10 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348026
Airborne fiber counting by phase-contrast microscopy for NYC DEP, sample dated July 2002.
15 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348222
Airborne fiber counting with phase-contrast microscopy; May 2002; DEP project.
11 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348207
Air sample analysis by phase-contrast microscopy for NYC DEP project, 5/2002.
12 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348127
Air sample analysis report (phase contrast microscopy) for NYC DEP project, Warren & Panzer Engineers.
14 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348091
Airborne fiber counting analysis for NYC DEP, WTC AR2, 7/4/02.
14 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307121
Air sample analysis, Phase Contrast Microscopy for Warren & Panzer; 2 hours turnaround.
10 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000348049
Airborne fiber counting and phase-contrast microscopy; NYC DEP job 1079.01.01, July 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348052
Phase-contrast microscopy and airborne fiber counting for NYC DEP, July 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000206737
Laboratory report detailing phase contrast microscopy results for airborne fiber counting at the S.W. Area site collected on June 30, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000161810
Phase contrast microscopy report for airborne fiber counting at the World Trade Center site dated May 2002.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348164
Airborne fiber counting by phase contrast microscopy for NYC DEP job; 8/18/2? report date appears.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000161747
Chain-of-custody form and monitoring log sheet for air samples collected at the World Trade Center site.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000348049
Airborne fiber counting and phase-contrast microscopy; NYC DEP job 1079.01.01, July 2002.
Similar indexed content
NYC-WTC_000348052
Phase-contrast microscopy and airborne fiber counting for NYC DEP, July 2002.
Similar indexed content
Laboratory report detailing phase contrast microscopy results for airborne fiber counting at the S.W. Area site collected on June 30, 2002.
Similar indexed content
NYC-WTC_000348164
Airborne fiber counting by phase contrast microscopy for NYC DEP job; 8/18/2? report date appears.
Similar indexed content
Laboratory report detailing phase contrast microscopy results for airborne fiber counting at the S.W. Area site collected on July 18, 2002.
Similar indexed content