AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: Warren & Panzer Engineers, P C PROJECT: NYC DEP, 30 W Broadway ATHENICA LABORATORY ID #: T02-08-113 DATE OF REPORT: 08/23/02 ENVIRONMENTAL SERVICES INC. ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 08/22/02 FILTER TYPE: M C E. EFFECTIVE FILTER AREA (mm^): 385 Tel. (718) 784-7490 Fax. (718) 784-4085 AVERAGE G.O. AREA (mm^): 0.012422

LABORATORY RESULTS

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cni’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cin’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5<S<5pm S>5.0um OOIA T02-08- Entrance to 1800 4 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 113-1787 decon 002A T02-08- North west on 1800 4 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 113-1788 ground level 003A T02-08- North area center 1800 4 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 113-1789 ground level 004A T02-08- North east area 1800 4 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 113-1790 ground level 005A T02-08- North area 1800 4 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 113-1791 adjacent to security box

ANALYST LABORATORY DIRECTOR E.Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

o Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. H Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. K If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is I to supplied solely for the convenience of the client. The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced S o except tn full and with pnor approval of AES Inc. o The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o I o o

CD

NYC-WTC_000347975

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000347975Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →