Airborne asbestos TEM log, project NYC DEP

Machine-extracted title · confidence 42%

TEM log and COC form for asbestos testing related to NYC DEP.

NYC-WTC_000347912
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z ■< Z ■<

o o g AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY co

O I CLIENT: Warren & Panzer Engineers, P. C. PROJECT: NYC DEP, 30 W Broadway “0 O c O LABORATORY ID #: T02-08-031 DATE OF REPORT: 08/08/02 CT O ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 08/08/02 o' Ca3 ATHENICA FILTER TYPE: M C E. EFFECTIVE FILTER AREA (mm^): 385 "0 o CD ENVIRONMENTAL SERVICES INC. AVERAGE G.O. AREA (mm^): 0.012422 CD ro Tel. (718) 784-7490 Fax. (718) 784^085 0 o o LABORATORY RESULTS c 3 CD 3 CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (It) ANAL AN ALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm^) AIR CONC. FILTER FOR FOR CIIRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5<S<5pm S>5.0pm 01 T02-08- By Decon 1440 5 0.0621 0.0043 0.0086 32.20 0.0043 0.0043 Chrys. NA 031-1362 02 T02-08- Inside work area 1440 5 0.0621 0.0043 <0.0043 <16.10 NA NA NA NA 031-1363 (West) 03 TO2-O8- Inside work area 1440 5 0.0621 0.0043 <0.0043 <16.10 NA NA NA NA 031-1364 (East) 04 T02-08- Inside work area 1440 5 0.0621 0.0043 <0.0043 <16.10 NA NA NA NA 031-1365 (South) 05 T02-08- Inside work area 1440 5 0.0621 0.0043 <0.0043 <16.10 NA NA NA NA 031-1366 (North)

ANALYST LABORATORY DIRECTOR E. Dimitrakas Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. o Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this lime frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for the convenience of the client. The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced S except in full and with prior approval of AES Inc. o The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o o I o o kO kO

Ui

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000347912Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →