NYC 9/11 Public Portal Document
TESTWELL LABORATORIES, INC.
Environmental Laboratory NYSEIAP# 11142
47 Hudson Street, Ossining, New York 10562 NVL4P # 2000830
AIHA # 100147
Transmission Electron Microscopy Results
Client: Warren & Panzer Engineers, P.C. Project #; NUF-001AB
228 East 45th Street
New York, NY 10017 Date Collected: 07/24/02
Date Rec*d (lab); 07/25/02
Sample Location: NYC DEP Analysis Date: 07/29/02
Side Facades TEM Analyst; D. McCarl
30 W. Broadway Analytical Method: AHERA
Field Technician: Client
Filter Type; MCE 0.45 micron
Avg.Grid Opening: 0.0121mm^
Grid
Lab Number Volume Grid Area Countable Asb. Concentration Concentration
Sample #: Sample Location: Openings
02TEM # Coll, (liters) Analyzed Structures Structures/mm’ Structures/cc
Analyzed
01 By Decon 5047 1600.0 4 0.048 0 <20.66 <0.005
02 By Entrance 5048 1600.0 4 0.048 0 <20.66 <0.005
03 Inside Work Area South ■ 5049 1600.0 4 0.048 0 <20.66 <0.005
Inside Work Area
04 Center 5050 1600.0 4 0.048 0 <20.66 <0.005
05 Inside Work Area East 5051 1600.0 4 0.048 0 <20.66 <0.005
06 BF 5052 0.0 N/A 0.048 N/A N/A N/A
07 BF 5053 0.0 N/A 0.048 N/A N/A N/A
08 Copped Blank 5054 0.0 N/A 0.048 N/A N/A N/A
Structures/mm’ Structures/cc^
[Total Average Concentrations <20.66 <0.005
This report is the confidential property of our clients. This certificate of anaiysis/report shall not be used by the client to claim product endorsement by the National
Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. The laboratory has no control over air sampling collection. This
certificate of anaiysis/report shall not be reproduced in full, without the written approval of Testwel! Laboratories, Inc.
Copyright © 2002 Testwell Laboratories, Inc.
LaDoratory Uirector/Apprcved Signatory