NYC 9/11 Public Portal Document
ATC Associates
104 East 25 Street, New York, NY 10010
Phone: (212) 353-8280 Fax: (212) 353-8306
Attn: Mr. Fabio Pedone Received: 7/27/02 9:20:00 PM
Wanen & Panzer Engineers , P.C. ATC Group#: 8608
228 E. 45th Street Analysis Date: 7/28/02
New York NY 10017
Fax: (212) 922-0630 Phone: (212) 922-0077
Project: NYC-DEP W & P File #: 1079.01.01
60 Broad Street, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos # Structures Sensitivity Concentration
Sample l^aiume Analyzed Asb Type(s) 0.5ft-S 5/1 fS/cc) (S/mm’) (S/cc) Notes
01 1560.00 0.0562 0 None Detected 0 0 0.0044 <17.79 <0.0044
8608 -I
02 1560.00 0.0562 0 None Detected 0 0 0.0044 <17.79 <0.0044
8608 -8
03 1560.00 0.0562 0 None Detected 0 0 0.0044 <17.79 <0.0044
8608 -7
04 1560.00 0.0562 0 None Detected 0 0 0.0044 <17.79 <0.0044
8608 -4
05 1560.00 0.0562 0 None Detected 0 0 0.0044 <17.79 <0.0044
S608 -5
ROMAN PEYSAKHOV MICHAEL A. GORYCKl, Ph.D.
Analyzed by: pproved by:
Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-iaboratory personnel. This lab is only responsible
for data repotted in structures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLIWTEM #101187-0. NY State ELAP #10879
Page ! uf I