Airborne asbestos TEM analysis, Warren & P.C.

Machine-extracted title · confidence 42%

TEM asbestos analysis report for NYC DEP project filing.

NYC-WTC_000346815
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z ■< Z ■<

o o co g AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY O I “0 o CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 87 Nassau Street c o CT o Ca3 ATHENICA LABORATORY ID #: T02-09-065 DATE OF REPORT: 09/19/02 o' o> ENVIRONMENTAL SERVICES INC, ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 09/19/02 "0 oo o TcL (71ft) 784-7-590 FILTER TYPE: M C E EFFECTIVE FILTER AREA (mm^): 385 cn CD Fax. (71ft) 784-*ea5 AVERAGE G.O. AREA (mm^): 0.013838 0 o o c LABORATORY RESULTS 3 o 3

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (It) ANAL AN ALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./ciTi’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5<S<5pm S>5.0pm 1 T02-09- Bottom of WA 1440 4 0.0554 0.0048 <0.0048 ■"^107“ NA NA NA NA 065-2395 center of WA 2 T02-09- Bottom of WA 1440 4 0.0554 0.0048 <0.0048 <18.07 NA NA NA NA 065-2396 south section of WA 3 T02-09- Bottom of WA 1440 4 0.0554 0.0048 0.0048 18.07 0.0048 <0.0048 Chrys. NA 065-2397 north section of WA 4 T02-09- Bottom of WA 1440 4 0.0554 0.0048 <0.0048 <18.07 NA NA NA NA 065-2398 west section of WA 5 T02-09- Within 5ft of 1440 4 0.0554 0.0048 <0.0048 <18.07 NA NA NA NA 065-2399 window to WA

S/ ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris o LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. O If AES inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is O O supplied solely for the convenience of the client. I The report relates only to items tested. This report must not be used to claim product endorsement by NVI AP or any other agency of the U.S. Uovemment. Test reports may not be reproduced o except in full and with prior approval of AES Inc o co The liability of Athenica Environmental Services Inc. with respect Io the services charged, shall tn no event exceed the amount of the invoice. o o

Ui

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000346815Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →