Z Z o o i AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY co

■0 o c o CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 85 Nassau Street CT o o ATHENICA LABORATORY ID #: T02-10-113 DATE OF REPORT: 10/19/02 o' cn EttviRONMENTAL SERVICES INC. ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 10/19/02 "0 o T 1 (7181784-7 90 FILTER TYPE: M.C.E. EFFECTIVE FILTER AREA (mm^): 385 o (71S 79X4085 AVERAGE G.O. AREA (mm"): 0.013838 o o o LABORATORY RESULTS c 3 CD CLIENT # LAB. ID # LOCATION VOLUME G.O.’s AREA ANALVT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. 3 (It) ANAL AN ALY SENSITIV. ASBESTO.S ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm‘) 0.5<S<5pm S>5.0pm 01 T02-10- Entrance to roof 1710 4 0.0554 0.0041 <0.0041 <18.07 NA NA NA NA 113-3251 02 T02-lo­ West side of roof 1710 4 0.0554 0.0041 <0.0041 <18.07 NA NA NA NA • ll 3-3252 03 T02-10- Center of roof 1 1710 4 0.0554 0.0041 <0.0041 <18.07 NA NA NA NA 113-3253 04 T02-10- Center of roof 2 1710 4 0.0554 0.0041 <0.0041 <18.07 NA NA NA NA 113-3254 05 T02-10- East side of roof 1710 4 0.0554 0.0041 <0.0041 <18.07 NA NA NA NA 113-3255

/Wo. ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 o Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. Air sampling cassettes will be stored for sixty (60) days. AES Inc,, should be notified withtn this time frame for atrue duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client Under these circumstances, the air concentration data is S supplied solely for the convenience of the client. o The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government Test reports may not be reproduced o except in full and with prior approval of AES Inc. o I The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice o o co o o Uli CIS o

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000346710Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →