Z ■< z o o § AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY o "0 o c CT o CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 83 Maiden Lane Ca3 ATHENICA LABORATORY ID #: T02-09-007 DATE OF REPORT: 09/06/02 o' O> ENVIRONMENTAL SERVICES INC. "0 ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 09/06/02 o ro TN. (718) 784-7490 Oi EFFECTIVE FILTER AREA (mm^): 385 03 Fax. (718) 784-W65 FILTER TYPE: M C E. AVERAGE G.O. AREA (mm^): 0.012422 O o o c 3 o LABORATORY RESULTS 3

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (strucL/cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE • (mm’) (struc./cm’) CONC. STRLCT. STRUCT. SPECIFY (str./mm’) O.S^S<5|Am S>S.(tjxm 9 T02-09- Decon 1460 5 0.0621 0.0042 0.0042 16.10 <0.0042 0.0042 Chrys. NA 007-2103 10 T02-09- On main roof 1440 5 0.0621 0.0043 <0.0043 <16.10 NA NA NA NA 007-2104 west side 11 T02-09- On main roof 1440 5 0.0621 0.0043 <0.0043 <16.10 NA NA NA NA 007-2105 north side 12 T02-09- Entrance to work 1440 5 0.0621 0.0043 <0.0043 <16.10 NA NA NA NA 007-2106 area 13 T02-09- On roof south 1440 5 0.0621 0.0043 <0.0043 <16.10 NA NA NA NA 007-2107 side

ANALYST LABORATORY DIRECTOR E. Dimitrakas Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 o Athenica Environmental Services Inc. (AES), is responsible only for information peruining to samples taken by its employees. Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for atrue duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is to supplied solely for the convenience of the client. The report relates only to items tested. This leport must not be used to claim product endorsement by NVLAP or any other agency of the U.S. ( jovemment Test reports may not be reproduced S o except in full and with prior approval of AES Inc. o The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o I o o co o o 2 cn

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000346425Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →