Airborne asbestos TEM analysis, Warren & [name], 12/2002

Machine-extracted title · confidence 32%

TEM asbestos analysis report; client Warren & [name], NYC DEP project, December 2002.

NYC-WTC_000346400
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z Z ■<

o o g AIRBORNE ASBESTOS ANAL YSIS BY TRANSMISSION ELECTRON MICROSCOPY co

O I CLIENT: Warren & Panzer Engineers, P C. PROJECT: NYC DEP, 80 Maiden Lane U o c o LABORATORY ID #: T02 12-027 DATE OF REPORT: 12/16/02 CT o o' o CD ATHENICA ANALYT. METHODOLOGY: AHERA FILTER TYPE:MCE DATE OF ANALYSIS: 12/16/02 EFFECTIVE FILTER AREA (mm^): 385 ■D ENVIRONMENTAi. SERVICES INC. o o AVERAGE G.O. AREA (mm"): 0.012820 3. o TeL (718) 78*-7-«0 03 Fax, (718) 78A-W85 o o LABORATORY RESULTS o c CLIENT # LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. 3 CD (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm^) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) O.S<S<5|am S>5.0p.m 1 T02-12- Front of building, 1800 4 0.0513 0.0042 <0.0042 <19.50 NA NA NA NA 027-4463 north 2 T02-12- Front of building, 1800 4 0.0513 0.0042 <0.0042 <19.50 NA NA NA NA 027-4464 south 3 T02-12- Front of building, 1800 4 0.0513 0.0042 <0.0042 <19.50 NA NA NA NA 027-4465 east 4 T02-12- Front of building, 1800 4 0.0513 0.0042 <0.0042 <19.50 NA NA NA NA 027-4466 west 5 T02-12- Front of building, 1800 4 0.0513 0.0042 0.0042 19.50 0.0042 <0.0042 Chrys. NA 027-4467 center

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Attienica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. o Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. If AE..S Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client Under these circumstances, the air concentration data is supplied solely for the convenience of the client. The report relates only to items tested. Titis report must not be used to claim product endorsement by NVLAP or any othei agency of the U.S. Government. Test reports may not be reproduced except in full and with prior approval of AES Inc. s O The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. O O I o o co o o 1 O

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000346400Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →