Airborne asbestos TEM report, NYC DEP project

Machine-extracted title · confidence 60%

TEM asbestos analysis report header for NYC DEP project; lab ID provided.

NYC-WTC_000346333
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z ■< z o o s AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY o I CLIENT: Warren & Panzer Engineers, P C PROJECT: NYC DEP, 80 Maiden Lane ■0 o c o LABORATORY ID #: T02-11-118 DATE OF REPORT: 11/29/02 CT o Ca3 DATE OF ANALYSIS: 11/29/02 o' ATHENICA ANALYT. METHODOLOGY: AHERA O> Ca5 EFFECTIVE FILTER AREA (mm^): 385 "0 o Ca5 Ca5 Tel. (718) 784-7490 9L Fax. (718) 784-4085 O LABORATORY RESULTS o o c CLIENT# LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. 3 o (It) ANAL AN ALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST 3 YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm^) (striic./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) O.S<S<5|ini S>5.0pm 01 T02-11- By the decon 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NA NA 118-4304 02 T02-11- Inside work area 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NA NA NA 118-4305 south 03 T02-11- Inside work area 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NA NA NA 118-4306 east 04 T02-11- Inside work area 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NA NA NA 118-4307 west 05 T02-11- Inside work area 1680 4 0.0537 0.0043 <0.0043 <18.61 NA NA NA NA 118-4308 north

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 o ■\tnenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees H Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumslaiices, the an concentration data it supplied solely for the convenience of the client. rhe report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the US. Government, lest reports may not be reproduced O except in full and with prior approval of AE.S Inc. o rhe liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o I o with respect to the sen'ices charged, shall in no event exceed the amount of the invoice. o co o o

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000346333Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →