NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Airborne asbestos TEM analysis, NYC DEP

Machine-extracted title · confidence 42%

TEM asbestos analysis report for NYC DEP, 75 [name].

NYC-WTC_000346291
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z Z -< o o g o AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY I ■0 o c o CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 75 Maiden Lane CT o Ca3 o> ATHENICA LABORATORY ID #: T02 09-021 DATE OF REPORT: 09/08/02 o' "0 ENVIRONMENTAL SERVICES INC. ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 09/08/02 ro o CD Tel. (7U) 784-7490 FILTER TYPE: M C E. EFFECTIVE FILTER AREA 385 3. Fax. (718) 784-4865 AVERAGE G.O. AREA (mm^): 0.013771 9L O o o c LABORATORY RESULTS 3 CD 3

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (It) ANAL AN ALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5<S<5^m S>S.0(im JB9 01 T02-09- On main roof 1440 SAMPLE NOT ANALYZED - FILTER MISSING 021-2169 (right) JB9 02 T02-09- On main roof 1440 4 0.0551 0.0049 0.0049 18.15 <0.0049 0.0049 Chrys. NA 021-2170 (middle) JB9 03 T02-09- On main roof 1440 4 0.0551 0.0049 0.0049 18.15 <0.0049 0.0049 Chrys. NA 021-2171 (left) JB9 04 T02-09- In room 1440 4 0.0551 0.0049 0.0097 36.31 0.0049 0.0049 Chrys. NA 021-2172 JB9 05 T02-09- In hallway 2 1440 4 0.0551 0.0049 <0.0049 <18.15 NA NA NA NA 021-2173 floor

4^4^ z

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. o Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. H If AES Inc., did not conduct the sampling, the reported airborne concentration was denved based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for the convenience of the client. The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced except in full and with prior approval of AES Inc. O fhe liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o o I o o (-O o o o co

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000346291Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →