NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, NYC DEP

Machine-extracted title · confidence 28%

AHERA TEM report; NYC DEP project, client Warren & [name], 08/17/02.

NYC-WTC_000346202
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: Warren & Panzer Engineers , P C. PROJECT: NYC DEP, 75 Maiden Lane LABORATORY ID #: T02-08-091 DATE OF REPORT: 08/17/02 ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 08/17/02 ATHENICA FILTER TYPE: M C E. EFFECTIVE FILTER AREA (mm^): 385 ENVIRONMENTAL SERVICES INC. AVERAGE G.O. AREA (mm"): 0 012422 Tel. (718) Tse-zeeo Fax. (718) ZM-AOeS

LABORATORY RESULTS

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm^) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./€m’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5<S<5um S>5.0nm 01 T02-08- On roof north 1350 5 0.0621 0.0046 <0.0046 <16.10 NA NA NA NA 091-1657 interior 02 T02-08- On roof near 1350 5 0.0621 0.0046 <0.0046 <16.10 NA NA NA NA 091-1658 motor room 03 T02-08- On roof near AC 1350 5 0.0621 0.0046 <0.0046 <16.10 NA NA NA NA 091-1659 unit 04 T02-O8- On roof west 1350 5 0.0621 0.0046 <0.0046 <16.10 NA NA NA NA 091-1660 interior 05 T02-08- On roof near 1350 5 0.0621 0.0046 <0.0046 <16.10 NA NA NA NA 091-1661 door to classroom

^3^

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 o Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. H Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was denved based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for the convenience of the client. o The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government l est reports may not be reproduced except in full and with prior approval of AES Inc. O O The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. I o o co o o kO co co co

NYC-WTC_000346202

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000346202Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos analysis report, August 2002

NYC-WTC_000206341

Laboratory results for airborne asbestos analysis by TEM using AHERA methodology for NYC DEP project dated August 26, 2002.

Similar indexed content

Compare copies and versions →