Asbestos TEM analysis report, NYC DEP facade

Machine-extracted title · confidence 28%

AHERA TEM analysis results; facade project for NYC DEP, client Warren & [name].

NYC-WTC_000346191
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBES I OS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 25 Maiden Lane ATHENICA laboratory id #: T02-09-067 DATE OF REPORT: 09/20/02 Etr^iROHMENTAt SERVICES INC. ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 09/20/02 TeU(7M,7iM.«90 FILTER TYPE: M.C.E. EFFECTIVE FILTER AREA 385 Fax. (718) 78^085 AVERAGE G.O. AREA (mm^): 0.013838

LABORATORY RESULTS

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm^) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm^) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mmb 0.5<S<5nm S>5.0nm 01 T02-09- Decon 1800 4 0.0554 0.0039 0.0039 18.07 <0.0039 0.0039 Chrys. NA 067-2405 02 T02-09- Entrance below 1800 4 0.0554 0.0039 0.0039 18.07 <0.0039 0.0039 Chrys. NA 067-2406 roof 03 T02-09- Center 1800 4 0.0554 0.0039 0.0039 18.07 0.0039 <0.0039 Chrys. NA 067-2407 04 T02-09- East side 1 1800 4 0.0554 0.0039 0.0078 36.14 <0.0039 0.0078 Chrys. NA 067-2408 05 T02-09- East side 2 1800 4 0.0554 0.0039 0.0039 18.07 <0.0039 0.0039 Chrys. NA 067-2409

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 o Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. H Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data i to supplied solely for the convenience of the client. s The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced o except in full and with prior approval of AES Inc. o The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o I o o co o o wo co cn

NYC-WTC_000346191

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000346191Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →