Airborne asbestos TEM results, NYC DEP, Oct 2002

Machine-extracted title · confidence 42%

TEM asbestos analysis; AHERA method, 10/19/02 report for NYC DEP.

NYC-WTC_000346134
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: Warren & Panzer Engineers, P.C PROJECT: NYC DEP, 21-23 Maiden Lane A TUt= Mir A LABORATORY ID #: T02-10-116 DATE OF REPORT: 10/19/02 A I nCIMlLzA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 10/19/02 ENVIRONMENTAL SERVICES INC. pjLTER TYPE' MCE EFFECTIVE FILTER AREA (mm"): 385 Tet. (718) 784-7490 AVERAGE G.O. AREA (mm"): 0.013838 Fax. (718) 784-4085

LABORATORY RESULTS

CLIENT # LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. (It) ANAL AN ALY SENSmV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm‘) 0.5<S<5nm S>5.0p.m 01 T02-10- IWA on roof center 1440 4 0.0554 0.0048 <0.0048 <18.07 NA NA NA NA 116-3267 of work area 02 T02-10- IWA on roof east 1440 4 0.0554 0.0048 <0.0048 <18.07 NA NA NA NA . 116-3268 section of work area 03 T02-10- IWA on roof north 1440 4 0.0554 0.0048 <0.0048 <18.07 NA NA NA NA 116-3269 section of work area 04 T02-10- IWA on roof west 1440 4 0.0554 0.0048 <0.0048 <18.07 NA NA NA NA 116-3270 section of work area 05 T02-lo­ OWA on stairwell 1440 4 0.0554 0.0048 <0.0048 <18.07 NA NA NA NA ll 6-3271 leading to roof 3ft. of door entrance

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris o LABORATORY CERTIFICATION NUMBERS; NVLAP 101958, ELAP 10955

Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. Air sampling cassettes will be stored for sixty (60) days AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is o supplied solely for the convenience of the client. o The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U..S- Government l est reports may not be reproduced Io except in full and with prior approval of AES Inc. o The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. co o o

cn co

NYC-WTC_000346134

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000346134Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →