NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Airborne asbestos TEM analysis, NYC DEP 9-11 site

Machine-extracted title · confidence 42%

Airborne asbestos TEM results for NYC DEP project tied to 9-11 site.

NYC-WTC_000345958
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRONJMICROSCOPY CLIENT: Warren & Panzer Engineers, P C. PROJECT: NYC DEP, 9-11 Maiden Lane LABORATORY ID #: T02-09-027 DATE OF REPORT: 09/08/02 ATHENICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 09/08/02 ENVIRONMENTAL SERVICES INC. EFFECTIVE FILTER AREA (mm^): 385 FILTER TYPE: M C E. TN. (718) 7»l-7<W0 AVERAGE G.O. AREA (mm^): 0.013771 Fax. (718) 784-W65

LABORATORY RESULTS

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALVT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIRCONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5<S<5nm S>5.0nm 01 T02-09- By the Decon 1365 5 0.0689 0.0041 <0.0041 <14.52 NA NA NA NA 027-2199 02 T02-09- IWA right side 1365 5 0.0689 0.0041 <0.0041 <14.52 NA NA NA NA 027-2200 ofWA 03 T02-09- IWA 1“ middle 1365 5 0.0689 0.0041 <0.0041 <14.52 NA NA NA NA 027-2201 ofWA 04 T02-09- IWA 2“ middle 1365 5 0.0689 0.0041 <0.0041 <14.52 NA NA NA NA 027-2202 OfWA 05 T02-09- IWA left side of 1365 5 0.0689 0.0041 <0.0041 <14.52 NA NA NA NA

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. o Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. H If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for the convenience of the client. The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S, Government Test reports may not be reproduced except in full and with prior approval of AES Inc S The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. O O O I o o co o o co CT CD CT

NYC-WTC_000345958

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000345958Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos analysis report, December 2002

NYC-WTC_000206354

Laboratory results for airborne asbestos analysis by TEM using AHERA methodology for NYC DEP project dated December 9, 2002.

Similar indexed content

Compare copies and versions →