AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY

CLIENT: Warren & Panzer Engineers, P.C. PROJECt: NYC DEP, 55 Liberty Street LABORATORY ID #: T02-10-143 DATE OF REPORT: 10/21/02 ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 10/21/02 ATHENICA FILTER TYPE: M C E. EFFECTIVE FILTER AREA (mm^): 385 ENVIRONMOITAU SERVICES INC. AVERAGE G.O. AREA (mm^): 0.013838 Tel. (718) 784-7490 Fax. (718) 784-1085 LABORATORY RESULTS

CLIENT # LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./em’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm^) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./niin’) O.S<S<5|iiii S>5.0p,ra 01 T02-10- Side walk north 1420 4 0.0554 0.0049 <0.0049 <18.07 NA NA NA NA 143-3419 02 T02-10- Side walk south 1420 4 0.0554 0.0049 <0.0049 <18.07 NA NA NA NA 143-3420 03 T02-10- Side walk east 1420 4 0.0554 0.0049 <0.0049 <18.07 NA NA NA NA 143-3421 04 T02-10- Side walk west 1420 4 0.0554 0.0049 0.0049 18.07 <0.0049 0.0049 Chrys. NA 143-3422 05 T02-10- Side walk central 1420 4 0.0554 0.0049 <0.0049 <18.07 NA NA NA NA 143-3423

ANALYST LABORATORY DIRECTOR E. Dimitrakas Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

o • Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. • Air sampling cassettes will be stored for sixty (60) days. AE.S Inc., should be notified within this time frame for a true duplicate analysis. K I • If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for the convenience of the client. S • The report relates only to items tested. This report must not be used to claim product endorsement by NVI.AP or any other agency of the U.S. Govenirnent. Test reports may not be reproduced o except in full and with prior approval of AES Inc. O • The liability of Athenica Environmental Services Inc. with respect to the seivice.s charged, shall in no event exceed the amount of the invoice. O I o o co o o kO

NYC-WTC_000345825

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000345825Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →