NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 6 pages

Airborne asbestos TEM analysis cover page

Machine-extracted title · confidence 33%

Cover page for airborne asbestos analysis by TEM, NYC DEP project 2 [name].

NYC-WTC_000345322–000345327
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z z ■<

o o g AIRBORNE ASBESTOS ANAEY^S BY TRANSMISSION ELECTRON MICROSCOPY co

CLIENT: Warren & Panzer Engineers, P. C. PROJECT: NYC DEP, 2 John St. ■D c o CT o LABORATORY ID #: T02-08-008 DATE OF REPORT: 08/02/02 o o' Ca5 4^ ATHENICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 08/02/02 ■D tn ENVIRONMENTAL SERVICES INC. FILTER TYPE: M.C.E. EFFECTIVE FILTER AREA (mm^): 385 O tiO Td. (718) 784-7490 AVERAGE G.O. AREA (itim^): 0.012422 3. ro 03 ro Fax. (718) 784-4085 0 o o LABORATORY RESULTS c 3 Q 3 CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.S<S<SiJ,m S>5.0p,m 01 T02-08- Exit from set 1530 5 0.0621 0.0041 0.0081 32.20 <0.0041 0.0081 Chrys. NA 008-1240 back 02 T02-08- East of set back 1530 5 0.0621 0.0041 <0.0041 <16.10 NA NA NA NA 008-1241 03 T02-08- West of set back 1530 5 0.0621 0.0041 <0.0041 <16.10 NA NA NA NA 008-1242 04 T02-08- South of set back 1530 5 0.0621 0.0041 <0.0041 <16.10 NA NA NA NA 008-1243 05 T02-08- North of set back 1530 5 0.0621 0.0041 0.0041 16.10 <0.0041 0.0041 Chrys. NA 008-1244

ANALYST LABORATORY DIRECTOR E. Dimitrakas Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. o Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. A If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is kJ I supplied solely for t6c convenience of the client. ro The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced except in full and with prior approval of AES Inc. The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o o I o o Ca2 O O Ca2

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000345322Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →