Airborne asbestos analysis by TEM, NYC

Machine-extracted title · confidence 59%

TEM AHERA analysis results for NYC DEP project, lab ID T02-11-039, 11/07/02.

NYC-WTC_000344693–000344698
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT; Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 100 Church Street ATHENICA laboratory id #: T02-11-039 DATE OF REPORT: 11/07/02 EMt/iRONMENTAL SERVICES wc ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 11/07/02 TH. (718) 784-7490 FILTER TYPE: MCE EFFECTIVE FILTER AREA (mn?l: 385 Fax. (718) 784-4085 AVERAGE G.O. AREA (mm"): 0.013433

LABORATORY RESULTS

CLIENT # LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. 0‘) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. rxiNC. TYPE ASBEST YZED ZED (struct./cni’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm^) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mni") 0.5<S<5pm S>5.0nm 01 T02-11- Decon 1440 4 0.0537 00050 <0.0050 <18.61 NA NA NA NA 039-3901 02 T02-11- Exit to the roof 1440 4 0.0537 0.0050 0.0199 74.44 0.0100 0.0100 Chrys NA 039-3902 03 T02-11- IWA west side of 1440 4 0.0537 0,0050 0.0050 18.61 <0.0050 0.0050 Chrys. NA 039-3903 WA 04 T02-11- IWA east side of 1440 4 0.0537 0.0050 <0.0050 <18.61 NA NA NA NA 039-3904 WA 05 T02-11- IWA 2"“ east side of 1440 4 0.0537 0.0050 <0.0050 <18.61 NA NA NA NA 039-3905 WA

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 o H Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. K I -Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. to If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for tlie convenience of the client The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced o except in full and with prior approval of AES Inc. o The liability of Athenica Environmental Services Inc. with respect Io the services charged, shall in no event exceed the amount of the invoice. I o o to

to Ui

O

NYC-WTC_000344693

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000344693Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →