Airborne asbestos analysis, AHERA, NYC DEP, 11/2002

Machine-extracted title · confidence 44%

AHERA TEM asbestos analysis for NYC DEP, 100 Church Street, November 2002.

NYC-WTC_000344597–000344602
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: Warren & Panzer Engineers, P C. PROJECT: NYC DEP, 100 Church Street ATHENICA LABORATORY ID #: T02-11-010 DATE OF REPORT: 11/02/02 environmental services inc. anaLYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 11/02/02 Tel. (718) 784-7490 FILTER TYPE: MCE EFFECTIVE FILTER AREA (mm^): 385 Fax. (718) 784-4085 AVERAGE G.O. AREA (mm^): 0.013433

LABORATORY RESULTS

CLIENT # LAB. ID # LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. (l») ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct/em’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm^) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm^) 0.5<S<5pm 8>5.0|un 01 T02-11- IWA east side of 1350 5 0.0672 0.0042 <0.0042 <14.89 NA NA NA NA 010-3725 WA 02 T02-11- IWA right side of 1350 5 0.0672 0.0042 <0.0042 <14.89 NA NA NA NA 010-3726 WA 03 T02-11- IWA middle ofWA 1350 5 0.0672 0.0042 <0.0042 <14.89 NA NA NA NA 010-3727 04 T02-11- IWA left side of 1350 5 0.0672 0.0042 <0.0042 <14.89 NA NA NA NA 010-3728 WA 05 T02-11- IWA 2"*’ left side of 1350 .5 0.0672 0.0042 <0.0042 <14.89 NA NA NA NA 010-3729 WA

ANALYST LABORATORY DIRECTOR E. Dimitrakas Spiro Dongaris

o LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 H K Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. I Air sampling cassettes will be stored for sixty (60) days AES Inc., should be notified within this time frame for a true duplicate analysis. to If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is s supplied solely for the convenience ofthe client. o The repon relates only to items tested. This report must not be used to claim product endorsement by NVL.AP or any other agency of the U.S. Government. Test reports may not be reproduced o o except in full and with prior approval of AES Inc. I The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o o to

to US.

o

NYC-WTC_000344597

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000344597Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →