AIRBORN^SBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY
CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 250 Broadway
ATHFWIPA laboratory ID #: T02 09 106 DATE OF REPORT: 09/28/02
A I nCIMlUA ANALYT. METHODOLOGY; AHERA DATE OF ANALYSIS; 09/28/02
ENVIRONMENTAL, SERVICES INC. TYPE* CE
EFFECTIVE FILTER AREA (mm"): 385
J'*'
rdx. (zlo)
AVERAGE G.O. AREA (mm"): 0.013838
LABORATORY RESULTS
CLIENT # LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB.
# (It) ANAL AN ALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST
YZED ZED (strucL/tm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE
(mm*) (struc./cni’) CONC. STRUCT. STRUCT. SPECIFY
(str./min’) 0.5<S<5|xin S>S.0)am
IDOl T02-09- The floor above the 1800 4 0.0554 0.0039 <0.0039 <18.07 NA N^ NA NA
106-2614 roof
ID02 T02-09- IWA exit to the 1800 4 0.0554 0.0039 <0.0039 <18.07 NA NA NA NA
106-2615 work area
ID03 T02-09- Exit to the work 1800 4 0.0554 0.0039 0.0039 18.07 0.0039 <0.0039 Chiys. NA
106-2616 area
ID04 T02-09- IWA left side of 1800 4 0.0554 0.0039 <0.0039 <18.07 NA NA NA NA
106-2617 work area
ID05 T02-09- IWA right side of 1800 4 0.0554 0.0039 <0.0039 <18.07 NA NA NA NA
106-2618 work area
ANALYST LABORATORY DIRECTOR
E. Sioukri Spiro Dongaris
LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955
Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees.
o Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis.
If AES Inc., did not conduct the sampling, the reported aiiboirc concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is
supplied solely for the convenience of the client.
The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U S. Government. Test reports may not be reproduced
to except in full and with prior approval of AES Inc.