NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Airborne asbestos TEM analysis results, NYC DEP, Aug 2002

Machine-extracted title · confidence 57%

TEM analysis results for asbestos, client Warren & [name], NYC DEP project at 196 Broadway.

NYC-WTC_000344165
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY

CLIENT: Warren & Panzer Engineers, PC. PROJECT: NYC DEP, 196 Broadway LABORATORY ID #: T02 08 065 DATE OF REPORT: 08/14/02 ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 08/14/02 ATHENICA FILTER TYPE: MCE EFFECTIVE FILTER AREA (mm^): 385 ENVIRONMENTAL SERVICES INC. AVERAGE G.O. AREA (mm^): 0 012422 Tel. (718) 784-7W F»x. (718) 78WO85

LABORATORY RESULTS

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (H) ANAL AN ALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc.ycm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5<S<5(rm S>S.0gm 01 T02-08- East side of roof 1620 4 0.0497 0.0048 0.0048 20/11 <0.0048 0.0048 Chrys. NA 065-1529 02 T02-08- West side of roof 1620 4 0.0497 0.0048 0.0048 20.13 <0.0048 0.0048 Chrys. NA 065-1530 03 T02-08- South side of 1620 4 0.0497 0.0048 <0.0048 <20.13 NA NA NA NA 065-1531 roof 04 T02-08- North side of 1620 4 0.0497 0.0048 0.0048 20.13 0.0048 <0.0048 Chrys. NA 065-1532 roof 05 T02-08- Center of roof 1620 4 0.0497 0.0048 <0.0048 <20.13 NA NA NA NA 065-1533

XMANALYST LABORATORY DIRECTOR E. Dimitrakas Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Atheniea Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. o Air sampling cassettes will be stored for sixty (60) days AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is K supplied solely for the convenience of the client. I fo The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced except in full and with prior approval of AES Inc O The liability of Atheniea Environmental Services Inc, with respect to the services charged, shall in no event exceed the amount of the invoice.

o o Io o

co Cn o

NYC-WTC_000344165

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000344165Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →