AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: Warren & Panzer Engineers, P. C. PROJECT: NYCDEP, 181 Broadway LABORATORY ID #: T02-08-060 DATE OF REPORT: 08/13/02 ATHFNICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 08/13/02 MI filter TYPE: M C E. EFFECTIVE FILTER AREA (mm^): 385 EHiziRONMENTALsaMCESuc. ^^ERAGE G.O. AREA(mmV. 0012422 T«l. (718) 784-7488 Fw. (718) 784-4885

LABORATORY RESULTS

CLIENT LAB. ID LOCATION VOLLME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # * (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str ./mm’) 0.5<S<5pm S>5.0pm 01 T02-08- By Entrance 1350 5 0.0621 0.0046 <0.0046 <16.10 NA naT" NA NA 060-1504 02 T02-08- Inside work area 1350 5 0.0621 0.0046 <0.0046 <16.10 NA NA NA NA 060-1505 West 03 T02-08- Inside work area 1350 5 0..0621 0.0046 <0.0046 <16.10 NA NA NA NA 060-1506 Center 04 T02-08- Inside work area 1350 5 0.0621 0.0046 <0.0046 <16.10 ■ NA NA NA NA 060-1507 East 05 T02-08- Inside work area 1350 5 0.0621 0.0046 <0.0046 <16.10 NA NA NA NA ^0-1508 North

ANALYST LABORATORY DIRECTOR E. Dimitrakas Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. o Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is H supplied solely for the convenience of the client. The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced except in full and with prior approval of AES Inc S The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o o o I o o to CD

cn

NYC-WTC_000344123

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000344123Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →