Document / 1 page

Airborne asbestos TEM analysis, NYC DEP project

Machine-extracted title · confidence 25%

Transmission electron microscopy asbestos analysis for NYC DEP project at Battery Place.

NYC-WTC_000343403
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z ■< Z o o co g o AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY I “0 o C o o CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 17 Battery Place CT DATE OF REPORT: 11/05/02 o' Ca3 4^ ATHENICA LABORATORY ID #: T02-11-020 ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS; 11/05/02 "0 Ca3 4^ ENVIRONMENTAL SERVICES INC. o O Ca5 Tel. (718) 784-7490 FILTER TYPE: M C E. EFFECTIVE FILTER AREA (mm^): 385 CD Fax. (718) 784-1085 AVERAGE G.O. AREA (mm^): 0.013433 0 o o LABORATORY RESULTS c 3 CD 3 CLIENT # LAB. ID # LOCATION VOLUME G.O/s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (strucL/cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mmb (struc./cni’) CONC. STRUCT. STRUCT. SPECIFY (strVmmb 0.5<S<5|xm S>5.0|jm IDOl T02-11- IWA by the decon 1470 4 0.0537 0.0049 <0.0049 <18.61 NA N^ NA NA 020-3775 ID02 T02-11- IWA 1st left side of 1470 4 0.0537 0.0049 <0.0049 <18.61 NA NA NA NA 020-3776 WA ID03 T02-11- IWA 2'“* left side of 1470 4 0.0537 0.0049 0.0049 18.61 0.0049 <0.0049 Chrys. NA 020-3777 WA ID04 T02-11- IWA 3rd left side of 1470 4 0.0537 0.0049 <0.0049 <18.61 NA NA NA NA 020-3778 WA 1005 T02-11- rWA 4th left side of 1470 4 0.0537 0.0049 <0.0049 <18.61 NA NA NA NA 020-3779 WA

ANALYST LABORATORY DIRECTOR E. Dimitrakas Spiro Dongaris

o LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 K Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. I Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for the convenience of the client o The report relates only to items tested this report must not be used to claim product endorsement by N VI Al' or any other agency of the U S Government. Test reports may not he reproduced o except in full and with prior approval of Al .S Inc. I The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o o

O CO

co

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000343403Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →