NYC 9/11 Public Portal Document
TESTWELL LABORATORIES, INC.
Environmental Laboratory NYS ELAP #11142
47 Hudson Street, Ossining, New York 10562 NVLAP #20008345
AIHA# 100147
Transmission Electron Microscopy Results
Client: Warren & Panzer Engineers, P.C. Project #: NUF-001AB
228 East 45th Street
New York, NY 10017 Date Collected: 07/30/02
Date Rec'd (lab): 07/31/02
Sample Location: NYC DEP Analysis Date: 08/01/02
F?oof Cleaning TEM Analyst: D. McCarl
St Peter Church Analytical Method; AHERA
Barclay St
Field Technician: Client
Filter Type: MCE 0.45 micron
Avg.Grid Opening: 0.0121mm’
Grid
Lab Number Volume Grid Area Countable Asb. Concentration Concentration
Sample #: Sample Location: Openings
02TEM # Coll, (liters) Analyzed Structures Structures/mm* Structures/cc
Analyzed
01 By Entrance 5505 1500.0 5 0.061 0 <16.53 <0.004
02 By South 5506 1500.0 5 0.061 0 <16.53 <0.004
03 By East 5507 1500.0 5 0.061 0 <16.53 <0.004
04 By North 5508 1500.0 5 0.061 0 <16.53 <0.004
05 By West 5509 1500.0 5 0,061 0 <16.53 <0.004
i
06 BF 5510 0.0 N/A 0.048 N/A N/A N/A
07 BF 5511 0.0 N/A 0.048 N/A N/A N/A
08 Copped Blank 5512 0.0 N/A 0.048 N/A N/A N/A
Structures/mm^ Structures/cc^
[Total Average Concentrations <16.53 <0.004
This report is the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National
Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. The laboratory has no control over air sampling collection. This
certificate of analysis/report shall not be reproduced in full, without the written approval of Testwell Laboratories, Inc.
Copyright © 2002 Testwell Laboratories, Inc.
Laboratory Uirector/Approved Signatory
CITY_21MC100_003009207
NYC-WTC_000343342
OCR can misread numbers and units. Confirm readings against the page image before using them.