NYC 9/11 Public Portal Document
LIBERTY
MUTUAL
Industrial Hygiene Air Sample Results
Summary for Week of 03/01/02 to03/08/02 ■
Elevated exposures to asbestos are based on the results of analysis by phase contrast microscopy
(PCM). This method counts all fibers detected that meet the criteria of “fiber”. Materials that are
not asbestos may be included in the reported analysis, 'fhese samples have been submitted for
further analysis by transmission electron microscopy (TEM) to make a definitive determination of
the fibers detected by PCM analysis.
Although no elevated hydrogen sulfide results were found during the week. Liberty Mutual has
recommended continuous monitoring for hydrogen sulfide during work in excavations. In past
weeks, we have had a few quantifiable hydrogen sulfide results (one area sample was actually above
the OEL). Also, there have been many anecdotal reports of hydrogen sulfide smells. Because of the
insidious nature and serious effects of exposures to excessive levels of hydrogen sulfide , we feel that
it is important to continuously monitor occupied spaces which are subject to build-up of “sewer
gases”.
Some of the columns in the attached summary may requite explanation:
Analyte Class - This column includes general category of the agents (substances) which were sampled.
# of Samples - This indicates how many individual samples were collected for the agent class listed.
# of Analysis - This is the number of individual analyses performed. If only one analysis is performed on
each sample, then the number of analytes will equal the number of samples. However, most samples are
analyzed for more than one agent as follows:
Metals: Aluminum, antimony, arsenic, barium, beryllium, cadmium, calcium, chromium, cobalt,
copper, iron, lead, magnesium, manganese, nickel, selenium, silver, thallium, tin, titanium, vanadium,
and zinc. Metal samples are sometimes also analyzed for total particulate.
Silica: Respirable dust, quartz, and cristobalite.
Acids: Hydrobromic acid, hydrochloric acid, hydrofluoric acid, nitric acid, phosphoric acid and
sulfuric acid
Sulfides: Hydrogen sulfide and sulfur dioxide
OEL - Occupational Exposure Limit is the lower of the OSHA PEL or ACGIH TLV. PELs are established
by an OSHA rule-making process and are the legal occupational exposure standards. TLVs are voluntary
guidelines for occupational exposure which are established by the American Conference of Governmental
Industrial Hygienists, a private professional organization.
Highest % OEL - This is the percentage of the occupational exposure limit (OEL) that the highest result
represents. This is the value in the “Highest Result” column divided by OEL and converted to a percentage.
Shift Adjusted OEL - The OEL reduced to compensate for the reduced recovery time and longer exposure
time posed by a 7 day per week , 12 hour shift work schedule.
CITY_21MC1OO_OO2989O24
NYC-WTC_000342008
OCR can misread numbers and units. Confirm readings against the page image before using them.