ES&H Air Monitoring Data preliminary, October 20,2001

Air Contaminant OSHA PEL-TWA, Work Area Total Number of Samples Percent (number) of Statistical Breakdown by MDL/QA limits Collected Samples Exceeding OSHA Work Area Per Work Area PEL-TWA Carbon Monoxide 50 parts per million (ppm) for 8 AMEC 2-both operators on pile 0%(0) Maximum concentration Measured as a gas using hour average (TWA). wasl47 ppm, with TWA for a direct reading 8 hours of 13ppm. instrument with data 200 ppm is recognized by recording. NIOSH as a maximum concentration never to be 5-three operators, one torch Maximum concentration exceeded. BOVIS cutter, and one not defined 0%(0) was 50 ppm with TWA for 8 task. hours of 1 ppm. Instrument has resolution of 1 ppm with an accuracy of ± 5%. Maximum concentration 3-torch cutter and operator was 16 ppm with TWA for 8 TULLY plus an undefined task. 0%(0) hours of 2 ppm.

Maximum concentration 4-311 equipment operators or was 27 ppm with TWA for 8 spotter hours of 0 ppm. TURNER 0%(0) Volatile Organics OSHA PEL as 8 hour TWA as BOVIS 2 (both were six hour Both samples less then Measured as gas phase follows: samples) MDL for 6 hour samples. organics in the breathing zone and includes:

Benzene 1 ppm 0%(0) <0.17 ppm Ethylbenzene 100 ppm 0%(0) <0.13 ppm Toluene 200 ppm 0%(0) <0.14 ppih Xylene 100 ppm 0%(0) <0.12 ppm

o H H

ro I—i

o ' I—i

o . I ' O : O N) . 5 CO •

(Jl

NYC-WTC_000341968

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000341968Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000360526

Preliminary air monitoring data with OSHA PEL-TWA comparisons for WTC site.

Similar indexed content

Compare copies and versions →