NYC 9/11 Public Portal Document
OSHA SAMPLING RESULTS SUMMARY AS OF 11/7
Asbestos: A total of642 air monitoring samples for asbestos have been taken. From 9/13
-9/21, 177 samples were taken in the financial district. They were taken on
OSHA personnel as they walked within certain predetermined zones. Results
revealed asbestos concentrations ranging from ND to .037 f/cc., well below
OSHA’s permissible exposure limit (PEL) of .1 f/cc.
After 9/21, sampling focused on the rubble pile and those workers working on
or immediately next to it. 63 of 465 samples exceeded OSHA’s limit via PCM
analysis. However, upon further analysis using discriminating counting
methods and/or TEM analysis, the number of asbestos fibers found dropped
dramatically to below detectable levels or well below .1 f/cc.
Carbon Monoxide; A total of 47 personal samples of workers on the rubble pile showed results
ranging from 1 ppm to 34 ppm which are well below the OSHA 50 ppm
permissible exposure limit.
Noise: OSHA has been conducting noise monitoring in the rubble pile. Twelve
personal samples have been conducted on employees performing (or working
near) various operations such as jack hammering. Employee’s exposure to the
noise range from 80.6 dBA to 89 dBA. OSHA’s permissible noise exposure
for construction is 90 dBA
Respirable
Silica: The overwhelming majority of the 226 silica samples show no detectable
levels of airborne silica. The highest sample result was approximately twice
the OSHA limit, whereas the next highest level was less than half of this limit.
Both of these levels were found on personnel working in the rubble pile; an
area where OSHA continues to encourage the use of respiratory protection.
Volatile Organic
Compounds: OSHA has taken 366 samples for (VOCs) such as acetaldehyde, acrolein,
acrylonitrile, benzene, 2-butanone„ carbofurans, chlorodiphenyl (PCB), ethyl
benzene, formaldehyde, freon, hexone, isocyanates (e.g. MDl, TDI),
perchloroethylene, phosgene, styrene, toluene, 1 -3 butadiene, trichloroethylene,
vinyl chloride, and xylene. Screening samples initially showed elevated levels
of some organic chemicals resulting from the fires burning in the rubble pile.
Subsequent personal and area samples show worker exposure levels to be
below OSHA limits. However, one personal sample result for benzene wa;
found to be at the 8-hr. OSHA Allowable Limit concentration of 1 ppm. Thi;
was found on a backhoe operator moving debris. See information below foi
polynucleated aromatics, Freon R-22, and dioxin.
Oxides of Nitrogen/ ‘
Sulfur: Sampling on grappler operators on the rubble pile, and oiremployees mannin
truck wash stations revealed trace levels of nitric oxide and nitrogen dioxide
Page 1 of 2
CITY_21MC1OO_OO2988937
NYC-WTC_000341948
OCR can misread numbers and units. Confirm readings against the page image before using them.