NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos PLM analysis, NY State ELAP 198.1

Machine-extracted title · confidence 37%

Asbestos analysis of sample by PLM; NY ELAP method listed.

NYC-WTC_000341673
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document From: 856-8543309 . To; Jeffrey J. Tasca Page: 2/2 Date. 10/11/2001 2:05.34 PM

aMSL Analytical, Inc. 107 Haddon Ave., Westmont, NJ 08108 Phone: (856)858-4800 Fax. (856) 858-4960 ^all; 8slenel®EM6L.com ^^2

Attn: Jeffrey J. Tasca Customer ID: OGDE54 AMEC Customer PO, 285 Davidson Avenue Somerset, NJ 08873 Received: 10/1W1 10:50 AM Fax: (732) 302-9504 Phone: 732-302-9500 040l’l5918 EMSL Order: Project: #1-741-80000/WTC EMSL Project ID:

Analysis Date: 10/11/2001

Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP 198.1 Method Non-Asbestos Asbestos Sample Location Appearance Treatment % Fibrous % Non-FIbrous % Type noT” STH FLR-BLDG. White Teased 25.00% Glass 75,00% Non-fibrous (other) None Detected 04011SI3ia-000i Fibrous Homogeneous NO. 2 STH FLR-BLDG Black Teased 00.00% Glass None Detected 04011SS>li<l<XI2 #6 Fibrous Homogeneous NO. 3 STH FLR-BLDG. Gray Teased 70.00% Glass 30.00% Non-fibrous (other) None Detected (M011S9ia2X)03 Fibrous Homogeneous NO. 4 3RDFLR-BLDG Gray Teased 3.00% Cellulose 47.00% Non-fibrous (other) None Detected o^ifS9ta<ioo'» #6 Fibrous 50.00% Glass Homogeneous NO. 5 LOWER LEVEL Brown/Gray Teased 40.00% Cellulose 53.50% Non-fibrous (other) 6.50% Chrysotile 010lf!)9ie-W09 Fibrous Heterogeneous NO. 6 B2 PARKING Blue Teased 45,00% Cellulose 55.00% Non-fibrous (other) None Detected (M011b913000e GARAGE Fibrous Homogeneous

Deloras Beard /Vialyst Stephen Siegel, CIH or other approved signatory

PLM has been knonn to miss asbestos in a small percentage of samples which contain asbestos. Negative PLM results cannot be guaranteed. Samples reported as <1% or none detected Should be tested with TEM. The above test report relates only to the items tested, this report may not be reproduced, except in full, without written approval by EMSL Analytical, Inc, The above test must not be used by the client to claim product endorsement by NVLAP nor any agency of the United states Government nalysis pertormed by EMSL Westmont (NVLAP »10104W), NY ELAP 10872

PLMPointCount-1 1

This FAX was sent by EMSL Analytical. Inc. For more information, please visit http://www.emsl.com.

CITY_21MC1OO_OO3OO6244

NYC-WTC_000341673

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000341673Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000388825

EMSL asbestos analysis order and TEM method; client, project and lab details.

Similar indexed content

Compare copies and versions →