WTC IH OPERATIONS Date: 05/06/02 To: Bruce Rottner - DDC CC: Bob Adams - DDC Ray Master - Bovis Lend Lease, LMB John Rabovsky - LMG Vic Hillman - LMG Mike Ramsey - LMG Donald A. Weber From: Charles W. Boone RE: WTC 5 Mold Assessment - Viable Results

Bruce,

Mike Donovan of ATC Associates and Don Weber conducted an assessment of mold on 4/23/02. Samples were coUected in two areas of WTC 5 B4, in the NE stairway leading from the loading dock and outside at the ATC trailer. Samples were for non-viable airborne fungi, viable airborne fungi and bacteria and bulk samples for microbial analysis. The results of the non-viable airborne fungi were provided to you in a memo on 4/25/02.

Results of the viable fungi samples support the results of the non viable fungi samples. Sample results show that most of the viable species are Aspergillus and PeniciUium. Results of these samples are included with this memo. AU samples were analyzed by Aerotech Laboratories in Phoenix, Arizona.

Viable bacteria concentrations were 17,100,000 efu/gram in the Kitchennette Area and 34,000,000 efu/gram in the Vault 1 area. 10 million efu/gram is considered a high concentration for bulk samples for bacteria.

Management and remediation of the mold in WTC 5, B4 , should proceed as outlined in Mr. Weber’s memo and in the specification submitted by ATC Associates on May 1, 2002.

Liberty Mutual’s industrial hygiene and medical consultation staff are available to assist DDC, BOVIS, and ATC with this effort. It is highly recommended that this service be utilized.

Bacteria Result Interpretation TypicaUy indoor air samples should be dominated primarily by Gram-positive cocci and to a lesser extent Gram-positive non-sporulating bacilli. These organisms are recognized in indoor air as originating primarily from human sources such as shedding human skin and mucous membranes. Highly elevated numbers of these organisms typicaUy indicate overcrowding of an occupied space or insufficient ventilation for the occupancy load. The term ventilation when used in this context means forced air ventilation with specific quantities of outdoor make up air to dilute interior generated contaminants.

1

CITY_21MC100_006695441

NYC-WTC_000341520

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000341520Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →