December 18, 2002
Mr. Bernard P. Orlan
Director, Environmental Health & Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Respirable Particulate Sampling
P.S. 89M
ATC Project No. 15-19125-0297
Dear Mr. Orlan:
ATC Associates Inc. (ATC) is pleased to provide this report of respirable particulate
sampling conducted on December 3-4 and 9-10, 2002, in the referenced school building.
The New York City Department of Education (DOE) requested this sampling to verify
that acceptable indoor air quality is being maintained.
SCOPE OF WORK
ATC conducted this evaluation to assess the concentration of respirable particulates
(PM2.5) within the building.
On each day, ATC collected one 24-hour sample of PM2.5 for gravimetric analysis using a
Micro Environmental Monitor® (MEM®), manufactured by SKC, Inc. The samples were
collected on pre-weighed PVC filters supplied and analyzed by PSC Analytical Services,
Inc., an American Industrial Hygiene Association-accredited laboratory in Reading, PA.
Tenzin Namgyal, Industrial Hygienist of ATC’s New York City office, conducted the
sampling consistent with generally accepted indoor air quality assessment practices. The
results of the sampling represent conditions found on the dates the samples were
collected.
EVAT.UATION CRITERIA
Currently, there are no regulatory' standards for indoor air quality in non-industrial
buildings, such as offices and schools.