NYC-WTC_000360042
ATC prepares IAQ measurements report for April 29, 2002 at P.S. 89M, NYC.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗ATC May 7, 2002 letter to BOE regarding IAQ measurements at PS 89M.
NYC-WTC_000340679–000340682OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
05^7/2002 12158 FAX._212 353 8306 ATC 0003/014
j J
Mr. Bernard P. Orlan May 7,2002 Indoor Air Quality Assessment Page 2 P. S- 89M ATCProiectNoJ5219125;0297 presented in this report should be used by the BOE as a guide to assess the need for further improvements in current indoor air quality control activities.
EVALUATION CRITERIA
Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications:
Ventilation for Acc^table Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditionsfor Human Occupancy (ASHRAE 5S-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).
Table 1 lists target guidelines for the parameters that ATC evaluated during this investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times.
TABLEI TARGET GUIDELINES FOR INPOOR AIR QUALITY PARAMETERS EVALUATED 'rtrfsms
Carbon Dioxide (CO2) <700 parts per million (ppm) ASHRAE62 above background level Carbon Monoxide 9 ppm ASHRAE 62 (adopted from (CO) USEPA NPAAQS) Respirable 65 micrograms per cubic meter USEPA NPAAQS Particulates (PM2 5) of air (pg/m^) 24-hour average 40 (xg/m^ 24-hour average USEPA - Recommendation for children / sensitive individuals Temperature Summer; 73-79°F at 50% RH ASHRAE 55 Winter: 68-75°? at 50% RH Relative Humidity 30-60% ASHRAE55 Total Volatile Organic Compounds 1 ppm AffitA (TVOC) USEPA - United States Enviiomnental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AIHA = American Industrial Hygiene Association
CITY_21MC100_012158255 NYC-WTC_000340680
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000360042
ATC prepares IAQ measurements report for April 29, 2002 at P.S. 89M, NYC.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000359970
IAQ field report for PS 89M with date June 2002 noted.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340509
ATC report on indoor air quality at P.S. 89M, Warren Street, June 2002.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360242
ATC memo transmitting IAQ measurements for PS 89M, March 6, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340699
ATC IAQ measurements conducted May 2, 2002 for P.S. 89M, NYC DOE.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360030
ATC reports IAQ measurements collected June 3, 2002 at P.S. 89M, NYC.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340473
ATC report of indoor air quality (lAQ) for P.S. 89M, 201 Warren Street.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360067
ATC indoor air quality measurements report for April 2002 at P.S. 89M, NYC.
11 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369736
ATC IAQ measurements report for PS 89M, May 2002.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340627
ATC May 16, 2002 memo re IAQ measurements at PS 89M.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313893
ATC IAQ measurements collected June 18, 2002 at PS 89M per BOE request.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340497
ATC report of indoor air quality measurements at P.S. 89M, early June 2002.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000369723
ATC IAQ measurements at PS 89M for BOE, May 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369765
ATC IAQ measurements at PS 89M for BOE, May 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400165
Indoor air quality measurements report for PS 89M, March 7, 2002, ATC.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000394453
IAQ measurements collected April 22, 2002 for P.S. 89M.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369813
IAQ measurements collected at PS 89M for BOE; May 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369833
ATC report of IAQ measurements at P.S. 89M requested by BOE, dated May 21, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000360042
ATC prepares IAQ measurements report for April 29, 2002 at P.S. 89M, NYC.
Similar indexed content
NYC-WTC_000359970
IAQ field report for PS 89M with date June 2002 noted.
Similar indexed content
NYC-WTC_000340509
ATC report on indoor air quality at P.S. 89M, Warren Street, June 2002.
Similar indexed content
NYC-WTC_000360242
ATC memo transmitting IAQ measurements for PS 89M, March 6, 2002.
Similar indexed content
NYC-WTC_000340699
ATC IAQ measurements conducted May 2, 2002 for P.S. 89M, NYC DOE.
Similar indexed content