NYSDOL - DOSH Regulations - Reg Page 34 of 44 (c) Loose/hanging asbestos material.Loose and hanging asbestos material shall be removed in accordance with the requirements of Subpart 56-12 of this Part.

(d) Repair of fireproofing/thermal insulation. After installation of hangers, brackets or other enclosure supports, and before installation of enclosure material, damaged areas of fireproofing/thermal insulation shall be repaired using a nonasbestos material as per Subpart 56-7 of this Part. Surfaces shall be prepared and replacement material applied in accordance with manufacturer's recommendations.

(e) Integrity of installation.Enclosure material shall be impact resistant and installed to provide an airtight barrier.

(I) Utility maintenance.Utilities shall be lowered as necessary and reinstalled in a manner which allows proper utilization and does not disturb the integrity of the enclosures. Utility maintenance shall not require the enclosures to be opened or disturbed.

(g) Ducts.Ducts insulated with asbestos material shall not be enclosed.

(h) Air plenums.Asbestos material-insulated air plenums, which are not readily accessible for inspection, shall not be enclosed.

(i) Cleanup.Cleanup shall be conducted in accordance with Subpart 56-15 of this Part.

(j) Marking or labeling.Enclosed asbestos material shall be conspicuously marked or labeled in order to warn persons of its presence.

Historical Note: Sec. filed July 7, 1987 eff. July 28, 1987. Subpart 56-15. CLEANUP PROCEDURES

Historical Note: Supbart (§§56-15.1-56-15.4) filed July 7, 1987 eff. July 28, 1987. § 56-15.1 General requirements.

The following cleanup procedures shall be required for all large and small abatement projects:

(a) Frequency for containerizing.Cleanup of accumulations of loose asbestos material shall be performed whenever enough loose asbestos material has been removed to fill a single leak-tight container of the type commensurate with the material properties. In no case shall cleanup be performed less than once prior to the close of each working day. Asbestos material shall be kept wet until cleaned up.

(b) Frequency for dust. Accumulations of dust shall be cleaned off all surfaces on a daily basis using HEPA vacuum and/or wet-cleaning methods.

(c) Frequency for enclosures.Decontamination enclosures shall be HEP A-vacuumed and/or wet-cleaned at the end of each shift.

(d) Cleanup tools and equipment. Accumulations of asbestos waste material shall be containerized utilizing HEPA vacuums or rubber or plastic dust pans, squeegees or shovels. Metal shovels shall not be used to pick up or move waste.

Historical Note: Sec. filed July 7, 1987 eff. July 28, 1987. § 56-15.2 Post-abatement requirements.

http;//www.labor.state.ny.us/html/safety/s56.htm 01/20/2001

CITY_21MC100_012156426

NYC-WTC_000340401

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340401Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000446470

State Part 56 asbestos chain-of-custody/document referencing NY Department of Labor; NYC files.

Similar indexed content

Compare copies and versions →