ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction. (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDSi Method; AHERA Final Rule, ERA Federal Register (40 CFR, Fart 763), Vol. 52, No, 210, October 30. 1587

Sample IdentificaVion Analysis Parameters

Project/Site: H.S. for Economics & Finance, IOC Trinity Pl., NYC TEM Sample No.; 5606 60121 Entire Huilding Date Received■■ 10/04/01 Grid Openings Analyzed:__ 4

Project Sample No.: HSEF-E-lO/3-43 Average Grid Opening: 106.00 um

Air Volume:lQ202^Cers Total Area Analyzed: Q.0450 min2

Filter Typ e: MCE 25 mm diam., Pore Size.: 0.45 um Analytica1 Sensitivity: 22.2 5/mm2 Effective Area: 3J5rQni2 0.0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct, Filter Air Fibers Bundles Clugfers Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 22.2 0.0047 155

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.coco 0

Total asbestos (includes ambiguous structures) 0 22.2 0 . 0047 155

Non-Asbestos 0 0 0 0 0 c 0.0 0.0000 N/A

No Identification 0 0 0 0 3 0 0. 0 0.9000 N/A

Totals (A_l Structures) 1 0 22 .2 0.0047 N/A

The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by;

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_009279601 NYC-WTC_000340292

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340292Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →