Asbestos fiber analysis, TEM, NYC, Oct 1987

Machine-extracted title · confidence 22%

TEM asbestos analysis with SAED/EDS methods, Oct 1987.

NYC-WTC_000340284
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATO Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. 'State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) with Fiber Identification by Selected-Area Electron Diffraction [SAED) and Energy-Diapersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Idencification Analysis Parameters

Project/Site: H.S. for Economics & Finance, 100 Trinity Pl,, NYC TEM Sample No.: 5606 60112 Entire Building Date Received: 10/04/^ Grid Openings Analyzed;__ 4

Project Sample No.; HSEF-E-10/3-34 Average Grid Opening: 106,00 um

Air Volume: 1320 liters Total Area Analyzed: 0.0450 mm2

Filter Tvoe: MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity ; 22,;2 s/Tim2 Effective Area: 365 mm2 0.0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Obseic/ed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct Struct > = 5um Struct/mm2 Struct/cc ngm/ni3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibcle Asbestos 0 0 0 0 0 0 0.0 0.0000 c

Arnhlgiicu.s 0 0 0 Q 0 0 0.0 0.0000 Q

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 C .0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A

The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_0092 79592

NYC-WTC_000340284

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340284Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000248388

TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

Compare copies and versions →