NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos fiber analysis, TEM, NYC, Oct 2001

Machine-extracted title · confidence 42%

TEM asbestos analysis for H.S. for Economics & Finance site, Oct 2001.

NYC-WTC_000340276
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmencal, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01

ASBEST0S_^LiSEK_ANALYSJS_BYjrRANSMISS20IL^LECTR0NJMICR0SC0PY^^ With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule. EPA Federal Register (40 CFR, Part 763), Vol. 52, Ko. 210, October 30, 1937

Sample Identification Analysis Parameters

Project/Site; H.5. for Economics & Finance, 100 Trinity Pl., NYC TEM Sample No.: 5606 60104 Entire Building Date Received: 10/04/01 Grid Openings Analyzed;__ 4

Project Sample No.: HSEF-E-10/3-26 Average Grid Opening: 106.00 urn

Air Volume: 1810 liters Total Area Analyzed: 0.0450 mm?

Filter Type: MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity:22:2 s2mni2 Effective Area: 385 mm2 Q.0Q47 5/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5un Struct/mm2 Struct/cc r.gm/m3

Chrysotile Asbestos 0 0 0 C 0 0 0.0 0.0000 c

Amphibole Asbestos 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 n 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbescos 0 0 0 0 0 0 0.0 0.ooco N/A No Identification 0 0 0 0 0 0 C.0 0.0000 N/A

Totals (Ail Structures) 0 0 0.0 0.0000 N/A

The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by. Report Reviewed by;

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC1OO_OO9279584

NYC-WTC_000340276

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340276Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244393

TEM analysis report for New Stuyvesant High School, Oct 2001.

Similar indexed content

Compare copies and versions →