ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule. EPA Federal Regi.gter (40 CFR, Part 753), Vol. 52, No. 210, October 30, 1987

SarnpleldantificatLon Analyses Parameters

Project/Site: H.S. for Economics & Finance, 100 Trinity Pl NTV"’ TEM Sample No.: 5606 60096 Entire Building Date Received: 10/04/01 Grid Openings Analy2ed:__ 4

Project Sample No.: HSEF-E-10/3-18 Average Grid Opening; 106.00 um

Air Volume :1820 Mt^rs Total Area Analyzed:^^04 5p mrn2

Filter T'ype: MCE 25 mm diam., Pore Size: 0.45 un Analytical Sensitivity: 22.2 s/mm2 Effective Area : 385 jTirri2 Q.0Q47 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nam/m3

Chrysotile Asbestos 0 0 0 1 22.2 0.0047 155

Amphibole Asbestos 0 c 0 0 0 0 0.G 0.0000 0

Ambiguous 0 0 0 0 0 0 C.0 0.0000 0

Total asbestos (includes ambiguous structures) 1 1 22 . 2 0.0047 155 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/.A No Identification 0 0 0 0 0 0 0.0 C . 0000 N/A

Totals (All Structures) 1 22 .2 0.0047 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

TVnalyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Micro.scopy

CITY_21MC100_009279577

NYC-WTC_000340268

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340268Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →