IvTa..tCTl 3.1 S Testing Lnb Znc., AMemberofTheMTGTOup-www.niaterials-testing.com

Corporate Headquarters ’ NY Metropolitan Regional Office Crouu 1529 Jericho Turnpike, New Hyde Park, NY 11040 • (516) 354-6600 • FAX (516) 354-6690 INSPECTION - ENGINEERING

Client: NYC Dept, of Design & Construction Report #: 03DDC-609 Page 1 of 2 30-30 Thomson Avenue Report Date: 10/28/03 Long Island City, NY 11101 Test Date: 10/23/03 Project: DDC-C-609 Contract: HWMWTCAIB Sample: Concrete Cores Test: Compressive Strength Method: ASTM C39 Sampled By: Client On Various Delivered By: MTL

Height Compr. Time Compr. Core # Diameter, Height Capped Area Load H/D Strength Corr. Strength Comp in. (inches) (inches) (Sq. in) (Lbs.) Corr. (PSD Factor (PSD lies

1 3.75 8.00 7.50 11.045 71890 1 6509 1.185 5493 Y 2 3.75 8.50 7.50 11.045 79190 1 7170 1.185 6051 Y 3 3.75 9.75 7.50 11.045 82140 1 7437 1.185 6276 Y 4* 3.75 9.25 5 3.75 11.25 7.50 11.045 67030 1 6069 1.185 5122 Y 6 3.75 8.50 7.50 11.045 66980 1 6064 1.185 5118 Y 7 3.75 8.75 7.50 11.045 80570 1 7295 1.185 6156 Y 8 3.75 8.75 7.50 11.045 74690 1 6763 1.185 5707 Y 9 3.75 9.75 7.50 11.045 63600 1 5758 1.185 4859 Y 10 3.75 9.50 7.50 11.045 66590 1 6029 1.185 5088 Y 11 3.75 8.00 7.50 11.045 63570 1 5756 1.185 4857 Y 12 3.75 9.50 7.50 11.045 60840 1 5509 1.185 4649 Y

T- "■ Remarks: Core #4 - Vertical Joint - not test was performed. /W< - Y.'E, Strength Keq.: 4000 PSI Reported To: A'-' //' /H wL-.. Lab #6070 Submitted By: (MaterialsiTftying T.ah, Inc. /

The above rcpcrtcd data is the propeitj' of the client. No reproduction of the Above data without the sole pcrm-ssnn of Materials Testing Lab, Inc. Materials Testing accepts no liability for work executed by others.

New York City • Long Island ■ Edison, NJ • Ventnor, NJ • Wallingford, CT • Dover, DE "PUT OUR GROUP TO THE TEST"

CITY_21MC100_007224247

NYC-WTC_000340152

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340152Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →