NYC 9/11 Public Portal Document
AMBIENT GROUP
Dioxins/Furans, HRGC/HRMS (8290)
Client Sample ID: 211909-12D
Lot-Sample#...! G2D190191 - 012 Work Order#...! EX6VP1AA Matrix....! SOLID
Date Sampled...! 04/18/02 Date Received^! 04/19/02 Instrument: 5D5
Prep Date..—.: 04/19/02 Analysis Date..: 04/24/02 Units.....! Pg/g
Prep Batch 2109509 Dilution Factor: 1 % Moisture;
DETECTION TEE TEQ
UMIT FACTOR CONCENTRATION
PARAMETER RESULT
2,3,7,8-TCDD 1100 1.000 1,100.000000
1,2,3,7,8-PeCDD 4000 0.500 2,000.000000
1,23,4,7,8-nxCDD 3100 0.100 310.000000
1,23,6,7,8-HxCDD 5000 0.100 500.000000
1,23,7,8,9-HxCDD 4800 0.100 480.000000
1,23,4,6,7,8-HpCDD 27000 0.010 270.000000
OCDD 52000 0.001 52.000000
23,7,8-TCDF 5600 CON 0.100 560.000000
1,23,7,8-PeCDF 6900 0.050 340.000000
23,4,7,8-PeCDF 8900 0.500 4,400.000000
133,4,7,8-HxCDF 11000 0.100 1,100.000000
1,2,3,6,7,8-HxCDF 9600 0.100 960.000000
23,4,6,7,8-HxCDF 8800 0.100 880.000000
1,2,3,7,8,9-HxCDF 840 0.100 84.000000
1,2,3,4,6,7,8-HpCDF 38000 0.010 380.000000
133,4,7,8,9-HpCDr 4400 0.010 44;000000
OCDF 20000 0.001 28.000800
Total TEQ Concentration 13,480.000000
PERCENT RECOVERY
INTERNALSTANDARDS RECOVERY LIMITS
13C-2,3.7,8-TCDD '57 40 -135
13G-l,2,3,7,8-PeCDD 55 40-135
13C-l,2,3,6,7,8-HxCDD 50 40-135
13C-l,2,3A6,7,8-HpCDD 63 40-135
13C-OGDD 69 40-135
13G-2,3,7,8-TCDF 43 40-135
13C-l,2,3.7,8-PeCDF 61 40 -135
13C-l,2,3,4,7,8-HxCDF 52 40-135
13C-l,2,3,4,6,7,8-HpCDF 63 40 -135
Notes:
TEF values are cited in U.S. Environmental Protection Agency, (1989) Inteiis ..ocean.., i; tsibnaSrag risb associated with exposures to mixtures ofchlorinated
-dibeazoflitans (CDDs and CDFs) and 1989 update. U.S. Enviionmentai Protection Agency, Risk Assessment forum. Washington, DC;
CON Confirmation analysis.
Sac_Sln(l_TEQ.RPT Rev.O ll/10/200(
CITY_21MC100_005087519
NYC-WTC_000339460