NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 176 pages

Technology overview, NYC health lab report

Machine-extracted title · confidence 25%

Laboratory note on technology tools; unclear project context.

NYC-WTC_000338737–000338912
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Article I Liu et al.

of myocardial infarction, angina, or conges­ later with a rotameter (model 92-04; Cole- ran from midnight to midnight to coincide tive heart failure. All asthmatic children had Parmer Instrument Co., Vernon Hills, IL), with the FRM2.5 measurements. physician-diagnosed mild to moderate asthma and to record on and off flow rates and Filter analysis. All filter weights were mieas- and had intermittent use of rescue medication change samplers. ured in either duplicate or triplicate using a (albuterol). .All subjects were nonsmokers liv­ Fixed-site monitoring. The indoor and seven-place electronic ultramicrobalance ing with nonsmokers, and they usually spent outdoor PM concentrations were measured (model UMT2; Mettler Toledo, Greifensee, more than 30 min a day outdoors. Most of with single-stage inertial Harvard Impactors Switzerland). The filters were equilibrated for the COPD and healthy subjects lived in (HI) (Air Diagnostics and Engineering, Inc., at least 24 hr before weighing. Both equilibra­ either group homes or private residences. Naples, ME) and 37-mra Teflon filters for tion and weighing were performed inside a Most of the cardiac subjects lived in private PMjo and PM2.5 (Marple et al. 1987). One controlled environmental chamber with con­ homes or apartments. All but one of the chil­ HI2 5-HI10 pair was located inside each home stant relative humidity (34.7 ± 2.5%) and tem­ dren lived in private homes. in the main activity room and connected to a perature (22.4 + 1.9°C) (Allen et al. 2001). Monitoring period. This study was con­ Medo pump (model vpO935a; Medo USA, Before weighing, the filters were passed ducted in 26 monitoring sessions, including Inc., Hanover Park, IL). Concurrently, one between two polonium-210 strips (500 pCi) to 13 sessions in each monitoring year; Year 1 Hl2,5-HIi() pair was located outside each eliminate any electrostatic charge on the filter. (October 1999-August 2000) and Year 2 home and connected to a Gast pump (model Each day, before the weighing sessions, the (.September 2000--May 2001) (Table 1). Each DOA-VI91-AA; Gast Manufacturing, Inc., microbalance was calibrated internally and session consisted of 10 consecutive monitoring Benton Harbor, MI). The on and off flow externally with four certified stainless steel days, starting at 1600 hr (± 2 hr) on Tuesdays rates were calibrated and recorded daily with weights (20, 50, 100, and 200 mg) to further and ending at 1600 hr (± 2 hr) on Fridays. Up the flow meter and later with a Cole-Parmer validate the internal calibration. to nine subjects (mean ± SD, 6 ± 2) per ses­ rotameter (model 34-39). All HI sampling Other information. At the beginning of sion were monitored simultaneously. The periods were for 24 hr at a flow rate of 10 each sampling session, technicians gathered average temperature, relative humidity, and L/min. HI2.5, HIjo, and HPEM2.5 vvere also information on the dwelling (apartment, home, wind speed were slightly higher in Year 1 collocated with the federal reference method etc.), proximity to a busy roadway, type of (temperature = 9.9 + d.O^C; relative humidity monitor for PM2,5 (FRM2.5) at the central parking garage, and type of heating (forced air, = 79.3 ± 8.4%; wind speed = 5.5 ± 0.9 m/scc) Beacon Hill site, which is located in a semircs- radiator, fireplace, etc.). During the study, each than in Year 2 (temperature = 7.9 ± 4.2’F; rel­ idential area (elevation, 300 feet) and is main­ subject kept a diary of time, activity, and loca­ ative humidity = 78.7 ± 10.6%; wind speed = tained by the Washington State Department tion with a 1 5-min resolution. The diary pro­ 4.7 ±1.9 m/sec), whereas the daily average of Ecology. This site has been validated as rep­ vided sufficient room co specify minutes used hours of stagnation (wind speed < 1.8 m/sec) resentative of the regional air quality in urban for each activity if more than one activity was was higher in Year 2 (11.6 + 6.2 hr) than in Seattle (Goswami et al. 2002). Duplicate sets conducted within the 15-min interval. In addi­ Year 1 (8.8 ± 6.2 hr). of tciiual-sitc HPEM2.5, HI2 5, and HIiq were tion, technicians recorded occurrence of events Personal monitoring. Personal PM2 5 expo- running at the same schedule as those at home that would potentially affect PM concentrations sures were determined using the Harvard sites (1600 hr to 1600 hr) for estimating preci­ at homes, including window opening, type of Personal Environmental Monitor for PM2 5 sion. One central-site HI2.5-HPEM2.5 pair cooking, incense burning, and house cleaning, (HPEM2,5; Harvard School of Public Health, Boston, MA). The small HPEM2.5 is a single- Table 1. Number of subjects by study group and session in the Seattle panel. stage inertial impactor with a 50% cut point of Study group 2.4 ±0.1 pm (Sioutas et al. 1999). The Year Starting date Session Asthmatics CHD CORD Heaithy Total HPEM2 5 was connected to a personal pump (AFC 400S; BGI, Inc., Waltham, MA) with a October 26 November 8 1 2 — r 0 5 J 4 ”1“

9 mass flow controller operated at 4 L/min. November 29 3 — 0 8 Pai ticle,s > 2.5 pm in diameter were originally 2000 January 10 4 — 0 3 6 9 collected on a porous metal impaction plate February 7 5 2 B coated with silicon oil immediately downstream February 21 6 0 3 J B March 6 7 1 3 3 7 of the inlet; particles < 2.5 pm bypassed the March 27 8 0 4 4 8 impaction plate and were collected on a 37-mm April 10 9 0 3 5 Teflon filter (polytetrafluoroethylene with sup­ May 1 10 0 5 8 port ring, model 225-1709; SKC, Inc., Eighty May 15 11 0 4 0 4 Four, PA). Because of an oil contamination July 10 12 1 4 / problem, the entire porous metal plate was July 31 13 1 1 4 September 25 1 2 4 6 replaced with silicon vacuum grease after the October 16 2 3 5 8 first four sessions (Demokritou et al. 2001). Novembers 3 6 B Each subject carried an HPEM2.5 in the Novembers? 4 4 6 breathing zone for 24 hr, except while sleep­ December 25 5 4 1 5 ing, showering, or using the restroom. The 2001 January 8 6 5 1 8 monitor was attached to the shoulder strap of January 22 7 3 3 6 February 5 8 3 5 either a backpack or a fanny pack that con­ February 26 9 4 4 8 tained the air pump. When the monitor was March 29 10 5 3 8 not worn, it was placed at an elevation of 3-5 April 16 11 3 2 5 feet (e.g., on a table) close to the subjects. April 30 12 4 1 5 Our field technicians visited the subjects daily May 14 13 1 3 4 to calibrate the pumps with a digital piston Total 33 40 56 33 187 flow meter (Drycal, DC-Lite; SKC Inc.), and About 50% of the subjects were monitored twice.

910 VOLUME 111 I NUMBER 7 I June 2003 • Environmental Health Perspectives CITY_21MC100_012178540

NYC-WTC_000338818

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338818Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →