DRAFT AHERA TEM’s 70 structures per square millimeter

EPA’s Asbestos Containing Materials in Schools Regulations, 40 CFR Part 763, Subpart E, specifies the clearance requirements for schools after asbestos abatement work. This, regulation was promulgated based on the Asbestos Hazard Emergency Response Act (AHERA). The purpose of the clearance criteria is to ensure that the schools are free of asbestos and safe for re-occupancy. The clearance criteria include a visual inspection and air sampling for asbestos. Thirteen samples must be collected including five indoor samples in the affected area, five outdoor samples, and three field blanks. The abatement is considered complete if the affected indoor environment passes a visual inspection and an average number of asbestos structures on the five filters from the indoor air sample contain no more than 70 structures per square millimeter of filter (70 s/mm“) for a minimum of a 1,200 liter air sample. EPA defines a structure as “microscopic bundle, cluster, fiber or matrix which may contain asbestos”, and a fiber is a structure greater than or equal to 0.5 micrometers in length having a length to width ratio of five to one (5:1).

The sensitivity of the AHERA TEM method is defined as 0.005 s/cc of air for a 1,200 liter air sample and filter analyses of eleven 0.057 mm^ grid openings. (A grid supports the sample filter during analysis.) The sensitivity is based on an estimated background fiber level in blank (unused) filters of one structure per ten grid openings (0.057 mm^). Hence one structure per ten grid openings (1 s/0.057 mm^) is equivalent to 17.5 s/mm\ In terms of s/cc of air sampled, the sensitivity is:

17.5 s/mm^ x 385mm~ = 0.0056 s/cm’ 1,200,000 cc

Asbestos structures are deposited on filter surfaces in a Poisson distribution. This non- uniform scattering makes one counted structure statistically indistinguishable from four counted structures. For clearance levels, then, the EPA multiplied the sensitivity (one structure counted, representing 17.5 s/mm^ and 0.0056 s/cm^) by four to yield 70 s/mm^ and 0.022 s/cm^, concentrations that are statistically distinguishable from background.

For asbestos abatement work, EPA allows TEM laboratories to analyze indoor air samples prior to analyzing field blank and outdoor air samples. If the 5 indoor samples contain an average of no more than 70s/mm“, analyses of the field blank and outdoor samples are not required. AHERA TEM analyses are often reported in s/mm" based on a minimum of a 1,200 liter sample.

CITY_21MC100_008980721

NYC-WTC_000338502

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338502Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →