Summary ofAsbestos Sampling Results Page 2 of 3 Address: 450 North End Ave. Date sampled: November 23, 200J

Results of Phase Contrast Microscopy (PCM) testing of air at 450 North End Ave, Nov. 23, 2001 Area Sampled Outside Common Residence 1 Residence 2

Sample Numbers A-0-15 A-C-15 A-Rl-15 A-R2-15

Concentration of Fibers <0.001 0.001 <0.001 <0.001 (ftcc)*

Concentration of Fibers in <0.001 to 0.001 <0.001 to 0.002 <0.001 to 0.003 <0.001 to 0.003 air in comparison locations (ftcc) NYC Re-occupancy 0.01 0.01 0.01 0.01 Standard (f/cc)** * Pcc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters of air. ** New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work (Rules of the City of New York, Title 15, Chapter 1)

ASBESTOS DUST TEST RESULTS

The dust and debris samples were examined by two different laboratory methods for asbestos fibers. Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM). PLM is used to define asbestos containing material in dust and debris. A material is considered to be asbestos containing material if it contains more than 1% asbestos using the PLM method. The PLM method only counts the larger asbestos fibers. Therefore, if results by PLM were not greater than 1% asbestos, the sample was then analyzed by the TEM method that does count the smaller fibers. However, TEM analysis is not used for regulatory purposes for dust samples.

Asbestos was found in the dust (greater than 1% using the PLM method) outside of your building. DOH and City Department of Environmental Protection (DEP) inspected the building after the sampling was conducted to determine if ftirther action was warranted. Additional testing and an assessment revealed that debris between the cracks of the tiles on the roof needed to be cleaned by an asbestos abatement contractor. The building owner hired a contractor and the debris was abated in accordance with DEP asbestos abatement regulations.

Low levels of asbestos were found in the dust in one of the residences in your building. The concentration of asbestos found (less than 1%) in this sample did not warrant the use of an asbestos abatement contractor.

Fibrous materials in dust found by PLM Analysis: Polarized Light Microscopy identifies asbestos fibers by shape and optical characteristics. Other fibers such as fabric (synthetics), paper (cellulose) and fiberglass may be identified in the analysis. The laboratory analyst counts the fibers present to give an estimate of fiber content. PLM is used for regulatory purposes for dust samples.

CITY_21MC100_008986838

NYC-WTC_000338360

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338360Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →