• December 2: first floor hall by exit 1; second floor hall by exit 1; third floor
hall by exit 1; roof.
The results of this sampling are as follows:
• Metals : The results of the metals analyses showed that most metals were not
detected either inside or outside of the school in any of the samples.
Chromium was detected at trace levels in all samples but at similar levels to
the method blank. Traces of iron were detected in two of the samples.
• Hydrocarbons: The results of the hydrocarbon analyses showed that most
samples had low to non-detectable levels of most of the hydrocarbon
compounds that were tested, although most samples also showed some level
of undifferentiated hydrocarbons, which could represent a material such as
mineral spirits. A few hydrocarbon compounds were detected in one or two
sample each at concentrations above the method detection limit, including
xylenes (maximum concentration of0.294 ppm), ethylbenzene (0.154 ppm),
tetrachloroethene (0.346 ppm), and chlorobenzene (0.129). There was
extensive painting being conducted inside the school during the sampling
period, as well as cleaning. The targeted hydrocarbon compounds detected in
a few samples, which included ethylbenzene and toluene, are often present in
certain paints or products used in painting. It is significant to note that the
samples collected on December 2 contained no specific hydrocarbon
compounds and only trace levels of unspecified hydrocarbon compounds. It is
stated in the ATC report that the paint odors, which had been strong inside the
school during the earlier sampling dates, had largely dissipated by December
2. Follow-up sampling for hydrocarbons and other volatile organic
1? C! h::. ;
• Particulates and Other Air Quality Parameters: Levels of carbon dioxide,
carbon monoxide, and relative humidity were within guideline ranges. Levels
of particulates (PM2.5) varied significantly during the period and appeared to
generally correlate with outdoor levels. On one of the days, November 30, the
particulate levels also exceeded the 65 ug/rn^ standard for normal populations.
It should be noted that 65 ug/m^ limit is established for outdoor conditions as
an average concentration over 24 hours. On three of the four dates, some
particulate measurements exceeded the guidance level of 40 ug/m^ established
by USEPA for sensitive receptors. It should be noted that there has been some
discussion that the method used to measure particulate levels may register
higher particulate levels than would be measured by performing a gravimetric
analysis of total particulates. ENVIRON has requested that the Board of
Education’s consultant perform a comparative analyses using the particulate
meter and gravimetric analysis to determine the comparability between the
two methods. The results of that comparison has not yet been received.