Alternatives for developing a surface loading screening value:
I. Experience standard (Millette, 1994a)
- Based on observation of many environments
- Example:
1000 s/cm2, is considered "low"
10,000 s/cm2, is considered "Above background"
100,000 s/cm2, is considered "High"
- We would need to integrate this with NYC background conditions
IL Beard's hypothetical room: (Beard , 1991)
- Assumes all material is suspended into the air column evenly
- Material on 1 cm2 into 243.8 cm3 column of air
(Effective K factor of 4 x 10’')
- This could be used for fibers and non-fibrous materials
- Example:
24 f/cm2 would yield 0.01 f/cc
0.012 ug/cm2 would yield 50ug/m3
III. K-factors (Millette, 1993b)
- Data is available to set K-factors for asbestos in controlled studies
- Asbestos derived K-factors, if applied to fibrous glass would be protective, since the
larger fibers take more energy to suspend and settle more quickly
- Limited data exist for K factors for particulates - Not sure if this could be applied to
other dust elements without an idea of size distribution.
- Example: for asbestos K=A/S
K Factor Air level Settled Dust level
1 X 10-" 0.01 10,000 s/cm2