ACTS New York lab asbestos analysis, 12/2001

Machine-extracted title · confidence 42%

Asbestos analysis of [name] by PLM via NY ELAP 198.1; client and project details.

NYC-WTC_000337551–000337552
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

12/24/01 17:05 012127770082 @002

Fiber glass is also the substance moat likely to be contributing to the symptoms experienced by people in the building. These symptoms can lead to serious respiratory problems in time. It is unconscionable to consider cleaning this material with ordinary duct cleaning methods. • The proposal from TechClean has a number of flaws. -- Some of the ductwork cannot be power washed and agitated as planned because it is actually constructed of sheet rock board instead of metal. This material has a surface which is very hard to clean and soaks up water. There are also likely to be joints that are not sealed or taped on the inside of these ducts that will make cleaning difficult. — The company makes it clear that if they cannot obtain access to an apartment they cannot “guarantee that there will be no crose-contamination caused by out cleaning process.’* Instead, there must be a plan in place to insure in advance that access will be obtainable and that no cross contamination will occur- -- The list of trainings that workers shall have includes "Asbestos awareness." Clearly, the workers should be fully asbestos abatement trained. -- The Project Manager should not only be experienced in projects of similar scope and size, and a certified air systems cleaning specialist, thia person should be certified to supervise asbestos abatement. -- Air monitoring by an independent company must be done to insure that the process is done correctly. • The Bader proposal should be modified to include TEM testing of a percentage (perhaps 15-20 percent) of the bulk sartiples. The TEM method usually detects larger amounts of fibers in WTC dust. • The dioxin procedures, as Bader has outlined, should also be done. We are seeing unexpected amounts of dioxins in certain building samples. SUMMARY. I have seen the dusty materials that are filtering back into the two apartments. Residents cannot be expected to live under such conditions. Every effort to fully identify this material must be made. The methods used to clean'it must be tailored precisely to the both the identity of this dust and to the hazards this dust poses to both cleaners and workers.

Respectfully submitted,

Monona Rossol, M.S., industrial hygienist

CITY_21MC100_0 06753239

NYC-WTC_000337552

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000337552Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →