standard. When compared against the NYC re-occupancy standard for asbestos fibers in community and residential buildings, all four samples were within the standard of 0.01 fibers per cubic centimeter (f/cc) of indoor air (see attached results). The maximum level of fibers in the air at your building was 0.002 f/cc. This air level is comparable to the air results from buildings located above 59* Street, which are not expected to be impacted by WTC materials. In the homes above 59* Street, levels of fibers found in the air ranged from less than 0.001 f/cc to 0.003 f/cc. This indicates the air levels for fibers from your building are similar to that seen in areas not impacted by the dust from the WTC collapse.

The attached table displays the settled dust asbestos results for your building. Each sample was examined by two different laboratory methods for asbestos fibers, Polarized Light Microscopy (PLM) and Transmission Electron Microscope (TEM). PLM is used to determine asbestos levels in bulk samples for regulatory purposes. A material is considered to be asbestos containing if it contains more than 1% asbestos using the PLM method. If results by PLM are not greater than 1% asbestos, the sample was then analyzed by the TEM method. TEM analysis is more sensitive and can detect smaller asbestos particles but is not used for regulatory purposes.

No asbestos was detected in the dust samples by PLM. Low levels of asbestos (less than one percent) were found in one of the outdoor samples by TEM. Slightly higher levels were found in the dust in the lobby (1.5%) by TEM. Asbestos fibers were not found in the dust samples from the two residences. For comparison, the settled dust samples collected at homes above 59* Street did not detect any asbestos by either laboratory method.

Although asbestos was found in low levels in the settled dust of your building and courtyard, air sampling indicates very few airborne fibers. However, asbestos fibers in settled dust may become airborne if disturbed by activities such as vacuuming. Since asbestos is present in the dust, we recommend that further cleaning of these areas using appropriate cleaning methods be conducted. Appropriate cleaning includes damp or wet mopping of hard surfaces and using vacuum cleaners equipped with a HEPA filter. Further information is enclosed. The New York City Department of Environmental Protection (DEP) has subsequently visited the building and reported that the building management conducted additional cleaning and observed that no visible dust was present in the areas where asbestos was detected.

Other WTC related materials might be present which could contribute to the eye, nose, and throat irritation experienced by residents in the area. The additional sampling we have done for dust, fiberglass, silica and other minerals may explain some of these conditions. Persons with existing respiratory conditions such as asthma, chronic bronchitis, or emphysema may find that their symptoms are exacerbated when they are exposed to these substances. Since these results have not yet been fully evaluated and since work continues at the World Trade Center site, we recommend that you continue to take precautions to avoid carrying dust on your shoes, clothes, etc. into your building from outdoors. In addition, we recommend that you continue cleaning using wet methods and/or vacuum cleaners equipped with a HEPA filter. See the enclosed DOH fact sheets for further information.

We have not yet received and completed review of all of the laboratory results of the other

J:\WTFILES\DOCS\wtc\70BatteryPlBldgl0-012402_l.doc

CITY_21MC100_013389745

NYC-WTC_000436256

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000436256Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000454030

DOH letter informing residents of asbestos sampling results at a WTC-related location.

Similar indexed content

Compare copies and versions →