NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Carpet cleaning and asbestos references, WTC study

Machine-extracted title · confidence 28%

Reference section discussing carpet cleaning and asbestos exposure in relation to WTC materials.

NYC-WTC_000337483–000337486
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document =Z=Z==5

[j Kelly McKinney - Millette-caipet sonication. pST Page 3]|

«n*no»4 le Mt «eniEo«su$rasciu3TaAinMQMaMMLVS6 NOSTR ° Number of isbestos anicimes counted in die anilpta Ings had been lemovcd from the cafeteria and dw area had been vacuumed EFA » Effective filler area of the final sampling fiber in square mini- whh a ceovcntional dry vacuum cleaner twice befoae the samples were meters cnUecrerl. Previous use and traffic patterns were ml taken kro account bi collecting the samples. Tbesimpleswettcollecaidlnatindommannerand OO = Number of grid openings analyzed some samples may have been from areas where an appliance such as a soft drink machine may have stood previously. The data which include some OOA = Average area of one TEM grid opening in s|uaic millimclen intetlaboratory comparisons are presented in Table I. Although, there appeals to be one oudiei m die data set, die idatlve standard deviation was SPL w Amount of caipet area sampled (in square feel or square centi­ calculated using all eight data paints for each merhud. The S, for the meters) mictDvacuuai lerdmitpie war 77% and for the bulk-carpet sonication proce­ dure was Sl% for Lab A ml 47% for Lab D, The mean tccovcry of the V = VOUme of sample fillet microvacuuming technique compared to the bulk-carpet sonication procedure was 1%.

DATA ON PRECISION AND PERCENT RECOVERY DISCUSSION Studies on the precision and level of asbestos of die bulk-carpet plcee ultrasonic shaking (sonicalian) technique and the mlm-vacuuming tech­ The answer lo the question about which method is best for assessing the nique were perfonnod as pan of the 1988 EPA study.* Siz samples were asbestos level in carpeting depends on die specific question being asked. In collected using each method from carpet eniflcially contaminated with Ute 1988 EPA carpel study the authots concluded that sonication of buik- approiimudy I billion (I x !(/•) asbestos stnictures per square foot (s/fl) caipet samples provided a mote precise and accurate estimate of asbestos or 1.08 X Kr str/cm^. The anificial coniaminalion was accomplished by conceitiniliotij in carpel dun die mlcrovacuianing sampling teeftnitpre. qxaying a known area of a carpel with a water solution Of known asbeslos Their conclusion was based In part on data wKcti showed that die mlcio- concentratiori. Because there was no Independent way lo measure the vacuuming technique was shown to recover signifleandy less asbestos from concent ration of asbestos on die carpet, no accuracy deteimination could be ihe carpel dun the ulmsotiic nique- made. However, die relative efficiency of recover of one melliad 10 Ilie The fact thu one technique is more cffideni in recovering Ebers than the other could be assessed. The mean asbeslos recovery using die micro­ other may be impoitan for tome audles invesitgiiing die cleaning of the vacuuming technique was 2.3 x lO’ s/ft’ (23 x 10* s/cm’). This was total caipcL However, there is reason Io believe that carpets can act as a apptokimately 3% of the mean recovery of butk-caroct st^alkxi trip for asbeslos fibers and But actlvltjcs short of carpet removal may not euraciion tedinique which was 7.9 x Hr s/fr (83 x Kr Stan’). The disturb asbeslos fibers which have woiked their way deep hso the carpet calculated coeffident of variaiion (CV) for the rtiicrovacuum technique was 166%. The CV for die bulk-carpetsonicatloo procedure was 43%. It should For those libers which can be readily teemraiiied Imo die ait train die be noted dial die values given in reference 2 lor sliucturei per square fool carpet surface during cleaning aciivilles, the mictovacuuraing procedure may are the correct values." There was an EnglislVmeWc conversion error in be more^iprapriaic. This is reasonable considering that the microvactnim- the article which provided Incorrect values for structures per square nterer ing procedure coUecis fibers frem the top layer of the ciipci and die bulk- throughout the paper. carpet sonicaiioa procedure ihakes out more fibers which may be embedded A similar set of tests using "real worliT carpeting that had been contami- de^ in the caipet pile. The data show that the sonication of bulk-carpet nalcd over a IS-year period of norm 11 use has been pctfonned by the samples is a more precise procethire than the microvacuuming procedure. authors' laboratories. The carpel samples were oolleeled from a cafeteria in However, the mictovacitumlng procedure has an advantage of being non­ the Social Security Adminisiration In Baltimore. Maryland. The cafeteria destructive While some building owncn may be willing to have a piece of had m acoustical pastel ceiling containing I lo 5% chtysolile. All fiiinisti- carpeting cut from their building If die carpel is to be removed. It is less

CITY_21MC100_003062598

NYC-WTC_000337485

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000337485Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →