2 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗Asbestos removal evaluation lab report, schools
Machine-extracted title · confidence 95%A twelve-page laboratory report evaluating methods for removing asbestos fibers from school buildings.
NYC-WTC_000144612–000144623Folder label: “SCHOOLS”

OCR status: ocr · source: ours
NYC 9/11 Public Portal Document i ERDPUEES wnalyst zed NYC-WTC_000144622 APPENDIX 4 NOSTR = Number of asbestos structures counted in the analysis EFA = Effective filter arca of the final sampling Alter in square milll- meters GO = Number of grid openings analyzed GOA = Average area of one TEM grid opening in square millimeters SPL = Amount of carpet area sampied (in square feet or square centi- meters) 143 V = Volume of sample filter DATA ON PRECISION AND PERCENT RECOVERY Seodics on the precision and level of asbestos of the bulk-carpet piece ultrasonic shaking (sonication) technique and the nique were perfonned as part of the 1988 EPA snudy. Six samples were collected using cach method from carpei anificlally contaminated with oy | ution (1 x 1) asbestos structures per square fot (s/f or 1.08 x 10° ste’cm? The artificial contamination was sccomplished by Spraying a known area of a carpet with a water solution of known asbestos concentration. Because there was no independent way t measure the concentration of asbestos on the carpet, no accuracy determination could be made. However, the relative efficiency of recover of one method to the other could be assessed. The mean asbestos recovery re micro: vacuuming technique was 2.3 x 10’ s/ft* (2.5 x 10° sém®). jinis was approximately see which wae 19 0 Ie ht Be nea extraction technique which was 7.9 x 10° 85 x 10° sf ie a The calculated coefficient of variation (CV) for the microvacuum technique was 166%. The CV for the bulk-carpet sonication procedure was 43%. It should be noted that the values given in reference 2 for structures per square foot are the correct vatues.!! There was an English/metric conversion error in the article which provided Incorrect values for structures per square meter throughout the paper. A similar set of tests using “real world” carpeting that had been contami- nated over a 15-year period of normal use has been performed by the authors® laboratories. The carpet sampics were collected from a cafeteria in the Social Security Administration in Balilmore, Maryland. The cafeteria had an acoustical plaster celling containing 1 to $% chrysoille. All furnish-
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
No available related records indexed in this group.
Filed elsewhere
4 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155920
Header page of a chain of custody document from the DEP Bureau of Air, Noise, and related services.
3 shared non-person entities · 1 shared topics · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
4 shared non-person entities · similarity 0.914
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156223
Memo transmitting an attached air quality report regarding 59 Maiden Lane, dated March 25, 2003.
1 shared non-person entities · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117668
Chain of custody documentation for bulk sampling and air monitoring at 385 South End Avenue Building 500.
4 shared non-person entities · 1 shared topics · similarity 0.912
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
5 shared non-person entities · 1 shared topics · similarity 0.912
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117757
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
4 shared non-person entities · 1 shared topics · similarity 0.912
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000105578
Administrative file header identifying records related to the property at 61 Broadway.
4 shared non-person entities · 1 shared topics · similarity 0.910
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117536
Chain of custody documentation for bulk sampling and air monitoring at 345 South End Avenue Building 100.
4 shared non-person entities · 1 shared topics · similarity 0.909
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149346
A chain of custody cover sheet for air monitoring samples sent to the EPA Region 1 laboratory in January 2003.
5 shared non-person entities · similarity 0.909
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117723
Chain of custody documentation for bulk sampling and air monitoring at 365 South End Avenue Building 300.
4 shared non-person entities · 1 shared topics · similarity 0.908
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000144509
A directive from the New York City Law Department regarding the preservation of original World Trade Center-related documents found in school files.
Filed in the same folder
NYC-WTC_000144510
Department of Environmental Protection letter agreeing with EPA and DOH recommendations to remove contaminated carpet from affected schools.
Filed in the same folder
NYC-WTC_000144512
Department of Environmental Protection letter agreeing with EPA and DOH recommendations to remove contaminated carpet from affected schools.
Filed in the same folder
NYC-WTC_000144514
Internal routing form for Department of Environmental Protection correspondence regarding school environmental issues.
Filed in the same folder
NYC-WTC_000144516
Fax cover sheet from the NYC Department of Environmental Protection Public Affairs Bureau dated August 7, 2002.
Filed in the same folder