NYC 9/11 Public Portal Document
□CT-31-2001 16=36 718 732 452 6464 718 732 452 6464 P.01/35
U.S. Environmental Protection Agency (www.epa.gov)
Air / Bulk / Wipe / Water Sampling Situation Report
Tnesday/Wednesday, October 30-31,2001 (1 PM)
Fixed Ambient Air Sampling Locations (Asbestos)
NYC / ER (Oct 26,1200 - 2400 hrs)
o All 20 samples analyzed were below the TEM AHERA standard.
NYC / ER (Oct 27,1200 - 2400 hrs)
o All 21 samples analyzed were below the TEM AHERA standard.
NYC / ER (Oct 28, 0001 - 1200 hrs)
0 All 21 samples analyzed were below the TEM AHERA standard.
0 1 sample was not collected (Location F) since pump was missing.
NYC / ER (Oct 28.0900 - 2400 hrs)
0 All 20 samples analyzed were below the TEM AHERA standard.
NYC / ER (Oct 29,0001 - 1200 hrs)
o All 20 samples analyzed were below the TEM AHERA standard.
NJ/ER (Oct 27)
o All 4 samples analyzed were below the TEM AHERA standard,
NJ/ER (Oct 29)
o All 4 samples analyzed were below the TEM AHERA standard.
Landfill Ambient Air Sampling Locations
• Fresh Kills (Oct 25, 0600 - 1830) - Asbestos
O 3 of 17 samples analyzed were above the TEM AHERA standard.
O Exceedance of the TEM AHERA standard occurred at the “Sift” Location #9A
(128 S/mm’), perimeter station at “Wash” Location #12B (115.6 S/mm^), and “Barge”
Location #13 (88.89 S/mm^).
o Preliminary evidence of predominantly large fibers present (awaiting confirmation fiom
lab) throu^out most of the samples.
0 Analysis of asbestos type for “Sift” Location #9A reveals 1 of 16 fibers to be amosite.
All other fibers identified, were chrysotile.
o Analysis of asbestos type for “Wash” Location #I2A reveals 1 of 3 fibers to be actinolite.
All other fibers identified were chrysotile.
0 2 samples (P Location #1, P Location #3) were not analyzed due to pump failures.
CITY_21MC100_0 03062581
NYC-WTC_000337454
OCR can misread numbers and units. Confirm readings against the page image before using them.